This might just be an Apple OEM version of the MK5065GSX, but here it is:

smartctl 6.1 2013-03-16 r3800 [x86_64-apple-darwin10.8.0] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
Sending command: "Execute SMART Short self-test routine immediately in off-line 
mode".
Drive command "Execute SMART Short self-test routine immediately in off-line 
mode" successful.
Testing has begun.
Please wait 2 minutes for test to complete.
Test will complete after Wed Jun  5 17:10:22 2013

Use smartctl -X to abort test.
admin@sync8% ./smartctl -x disk0      
smartctl 6.1 2013-03-16 r3800 [x86_64-apple-darwin10.8.0] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     TOSHIBA MK5065GSXF
Serial Number:    X1K1CC9ZT
LU WWN Device Id: 5 000039 393308be0
Firmware Version: GP006B
User Capacity:    500,107,862,016 bytes [500 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    5400 rpm
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ATA8-ACS (minor revision not indicated)
SATA Version is:  SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is:    Wed Jun  5 17:11:11 2013 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM level is:     128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is:   Enabled
ATA Security is:  Disabled, frozen [SEC2]

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                (  120) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        ( 166) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     PO-R--   100   100   050    -    0
  2 Throughput_Performance  P-S---   100   100   050    -    0
  3 Spin_Up_Time            POS--K   100   100   001    -    1608
  4 Start_Stop_Count        -O--CK   100   100   000    -    1755
  5 Reallocated_Sector_Ct   PO--CK   100   100   050    -    0
  7 Seek_Error_Rate         PO-R--   100   100   050    -    0
  8 Seek_Time_Performance   P-S---   100   100   050    -    0
  9 Power_On_Hours          -O--CK   071   071   000    -    11698
 10 Spin_Retry_Count        PO--CK   135   100   030    -    0
 12 Power_Cycle_Count       -O--CK   100   100   000    -    74
191 G-Sense_Error_Rate      -O--CK   100   100   000    -    0
192 Power-Off_Retract_Count -O--CK   100   100   000    -    5
193 Load_Cycle_Count        -O--CK   001   001   000    -    990801
194 Temperature_Celsius     -O---K   100   100   000    -    38 (Min/Max 21/55)
196 Reallocated_Event_Count -O--CK   100   100   000    -    0
197 Current_Pending_Sector  -O--CK   100   100   000    -    0
198 Offline_Uncorrectable   ----CK   100   100   000    -    0
199 UDMA_CRC_Error_Count    -O--CK   200   200   000    -    0
220 Disk_Shift              -O----   100   100   000    -    8253
222 Loaded_Hours            -O--CK   090   090   000    -    4120
223 Load_Retry_Count        -O--CK   100   100   000    -    0
224 Load_Friction           -O---K   100   100   000    -    0
226 Load-in_Time            -OS--K   100   100   000    -    324
240 Head_Flying_Hours       P-----   100   100   001    -    0
254 Free_Fall_Sensor        -O--CK   100   100   000    -    0
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: 48-bit ATA commands not 
implemented
Read GP Log Directory failed

SMART Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00           SL  R/O      1  Log Directory
0x01           SL  R/O      1  Summary SMART error log
0x02           SL  R/O     51  Comprehensive SMART error log
0x06           SL  R/O      1  SMART self-test log
0x09           SL  R/W      1  Selective self-test log
0x80-0x9f      SL  R/W     16  Host vendor specific log
0xe0           SL  R/W      1  SCT Command/Status
0xe1           SL  R/W      1  SCT Data Transfer

SMART Extended Comprehensive Error Log (GP Log 0x03) not supported

SMART Error Log Version: 1
No Errors Logged

SMART Extended Self-test Log (GP Log 0x07) not supported

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%     11698         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Status Version:                  2
SCT Version (vendor specific):       1 (0x0001)
SCT Support Level:                   1
Device State:                        Active (0)
Current Temperature:                    38 Celsius
Power Cycle Min/Max Temperature:     27/53 Celsius
Lifetime    Min/Max Temperature:     21/55 Celsius
Under/Over Temperature Limit Count:   0/0
SCT Temperature History Version:     2
Temperature Sampling Period:         1 minute
Temperature Logging Interval:        1 minute
Min/Max recommended Temperature:      5/55 Celsius
Min/Max Temperature Limit:            5/55 Celsius
Temperature History Size (Index):    478 (255)

Index    Estimated Time   Temperature Celsius
 256    2013-06-05 09:14    34  ***************
 ...    ..( 41 skipped).    ..  ***************
 298    2013-06-05 09:56    34  ***************
 299    2013-06-05 09:57    35  ****************
 300    2013-06-05 09:58    35  ****************
 301    2013-06-05 09:59    35  ****************
 302    2013-06-05 10:00    34  ***************
 ...    ..( 30 skipped).    ..  ***************
 333    2013-06-05 10:31    34  ***************
 334    2013-06-05 10:32    35  ****************
 335    2013-06-05 10:33    35  ****************
 336    2013-06-05 10:34    34  ***************
 ...    ..( 17 skipped).    ..  ***************
 354    2013-06-05 10:52    34  ***************
 355    2013-06-05 10:53    35  ****************
 356    2013-06-05 10:54    34  ***************
 ...    ..(  2 skipped).    ..  ***************
 359    2013-06-05 10:57    34  ***************
 360    2013-06-05 10:58    35  ****************
 361    2013-06-05 10:59    34  ***************
 ...    ..( 31 skipped).    ..  ***************
 393    2013-06-05 11:31    34  ***************
 394    2013-06-05 11:32    35  ****************
 395    2013-06-05 11:33    34  ***************
 ...    ..( 23 skipped).    ..  ***************
 419    2013-06-05 11:57    34  ***************
 420    2013-06-05 11:58    35  ****************
 ...    ..( 68 skipped).    ..  ****************
  11    2013-06-05 13:07    35  ****************
  12    2013-06-05 13:08    36  *****************
  13    2013-06-05 13:09    35  ****************
 ...    ..(  6 skipped).    ..  ****************
  20    2013-06-05 13:16    35  ****************
  21    2013-06-05 13:17    36  *****************
 ...    ..(231 skipped).    ..  *****************
 253    2013-06-05 17:09    36  *****************
 254    2013-06-05 17:10    38  *******************
 255    2013-06-05 17:11    38  *******************

SMART WRITE LOG does not return COUNT and LBA_LOW register
SCT (Get) Error Recovery Control command failed

Device Statistics (GP Log 0x04) not supported

ATA_READ_LOG_EXT (addr=0x11:0x00, page=0, n=1) failed: 48-bit ATA commands not 
implemented
Read SATA Phy Event Counters failed

------------------------------------------------------------------------------
How ServiceNow helps IT people transform IT departments:
1. A cloud service to automate IT design, transition and operations
2. Dashboards that offer high-level views of enterprise services
3. A single system of record for all IT processes
http://p.sf.net/sfu/servicenow-d2d-j
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to