smartctl 5.43 2012-06-30 r3573 [i686-w64-mingw32-win7(64)-sp1] (sf-5.43-1)
Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     ST320LT007-9ZV142
Firmware Version: 0004LVM1
User Capacity:    320,072,933,376 bytes [320 GB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Wed Aug 28 13:33:44 2013 CEDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                (    0) seconds.
Offline data collection
capabilities:                    (0x73) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        No Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (  62) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x303b) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   111   099   034    Pre-fail  Always       
-       35564208
  3 Spin_Up_Time            0x0003   098   098   000    Pre-fail  Always       
-       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       
-       182
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x000f   075   060   030    Pre-fail  Always       
-       37056939
  9 Power_On_Hours          0x0032   099   099   000    Old_age   Always       
-       1262 (254 180 0)
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       
-       182
184 End-to-End_Error        0x0032   100   100   099    Old_age   Always       
-       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       
-       0
188 Command_Timeout         0x0032   100   097   000    Old_age   Always       
-       45
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       
-       0
190 Airflow_Temperature_Cel 0x0022   061   051   045    Old_age   Always       
-       39 (Min/Max 24/43)
191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always       
-       6
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       
-       8
193 Load_Cycle_Count        0x0032   095   095   000    Old_age   Always       
-       10754
194 Temperature_Celsius     0x0022   039   049   000    Old_age   Always       
-       39 (0 16 0 0 0)
195 Hardware_ECC_Recovered  0x001a   055   039   000    Old_age   Always       
-       35564208
196 Reallocated_Event_Count 0x000f   099   099   030    Pre-fail  Always       
-       1237 (24338 0)
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       
-       0
250 Read_Error_Retry_Rate   0x0000   001   001   000    Old_age   Offline      
-       151640
251 Unknown_Attribute       0x0000   100   001   000    Old_age   Offline      
-       9133
252 Unknown_Attribute       0x0000   100   001   000    Old_age   Offline      
-       3506
254 Free_Fall_Sensor        0x0032   100   100   000    Old_age   Always       
-       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%      1262         -
# 2  Vendor (0x50)       Completed without error       00%      1212         -
# 3  Short offline       Completed without error       00%      1212         -
# 4  Vendor (0x50)       Completed without error       00%       115         -
# 5  Short offline       Completed without error       00%       115         -
# 6  Vendor (0x50)       Completed without error       00%         0         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
Learn the latest--Visual Studio 2012, SharePoint 2013, SQL 2012, more!
Discover the easy way to master current and previous Microsoft technologies
and advance your career. Get an incredible 1,500+ hours of step-by-step
tutorial videos with LearnDevNow. Subscribe today and save!
http://pubads.g.doubleclick.net/gampad/clk?id=58040911&iu=/4140/ostg.clktrk
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to