smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.10.18-1-lts] (local build) Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION === Device Model: Corsair Force SSD Serial Number: 1250659300FF12600003 LU WWN Device Id: 0 000000 000000000 Firmware Version: 5.05 User Capacity: 240,057,409,536 bytes [240 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3 SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s) Local Time is: Mon Nov 11 11:29:55 2013 KRAT SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM level is: 254 (maximum performance) Rd look-ahead is: Disabled Write cache is: Enabled ATA Security is: Disabled, frozen [SEC2] Unexpected SCT status 0x0010 (action_code=4, function_code=2) Wt Cache Reorder: N/A === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x02) Offline data collection activity was completed without error. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 48) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x0021) SCT Status supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-- 100 100 050 - 3556294 5 Reallocated_Sector_Ct PO--CK 100 100 003 - 0 9 Power_On_Hours -O--CK 100 100 000 - 105 (252 94 0) 12 Power_Cycle_Count -O--CK 100 100 000 - 8 171 Unknown_Attribute -O--CK 000 000 000 - 0 172 Unknown_Attribute -O--CK 000 000 000 - 0 174 Unknown_Attribute ----CK 000 000 000 - 18 177 Wear_Leveling_Count ------ 000 000 000 - 0 181 Program_Fail_Cnt_Total -O--CK 000 000 000 - 0 182 Erase_Fail_Count_Total -O--CK 000 000 000 - 0 187 Reported_Uncorrect -O--CK 100 100 000 - 0 194 Temperature_Celsius -O---K 128 030 000 - 128 (0 30 0 30 0) 195 Hardware_ECC_Recovered --SRC- 120 120 000 - 3556294 196 Reallocated_Event_Count PO--CK 100 100 003 - 0 201 Unknown_SSD_Attribute --SRC- 120 120 000 - 3556294 204 Soft_ECC_Correction --SRC- 120 120 000 - 3556294 230 Unknown_SSD_Attribute PO--C- 100 100 000 - 100 231 Temperature_Celsius PO--C- 100 100 010 - 0 233 Media_Wearout_Indicator ------ 000 000 000 - 90 234 Unknown_Attribute -O--CK 000 000 000 - 135 241 Total_LBAs_Written -O--CK 000 000 000 - 135 242 Total_LBAs_Read -O--CK 000 000 000 - 31 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL,SL R/O 1 SATA Phy Event Counters 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xb7 GPL,SL VS 16 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log (GP Log 0x03) not supported SMART Error Log not supported SMART Extended Self-test Log Version: 1 (1 sectors) No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 0 (0x0000) SCT Support Level: 1 Device State: Active (0) Current Temperature: ? Celsius Power Cycle Min/Max Temperature: 127/-127 Celsius Lifetime Min/Max Temperature: 0/ 0 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 0 (Unknown, should be 2) Temperature Sampling Period: 1 minute Temperature Logging Interval: 10 minutes Min/Max recommended Temperature: 0/ 0 Celsius Min/Max Temperature Limit: 0/ 0 Celsius Temperature History Size (Index): 0 (71) Temperature History is empty SCT Error Recovery Control command not supported Device Statistics (GP Log 0x04) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 4 Device-to-host register FISes sent due to a COMRESET 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC 0x0002 2 0 R_ERR response for data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS ------------------------------------------------------------------------------ November Webinars for C, C++, Fortran Developers Accelerate application performance with scalable programming models. Explore techniques for threading, error checking, porting, and tuning. Get the most from the latest Intel processors and coprocessors. See abstracts and register http://pubads.g.doubleclick.net/gampad/clk?id=60136231&iu=/4140/ostg.clktrk _______________________________________________ Smartmontools-database mailing list Smartmontools-database@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/smartmontools-database