Hello,
Please add the Hitachi HTS725050A9A360 disk to the database.
Attached is smartctl output for HTS725050A9A360 disk.
Thanks,
ChRoot.
smartctl 6.2 2013-07-26 r3841 [i686-linux-3.11.6-4-desktop] (SUSE RPM)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: Hitachi HTS725050A9A360
Serial Number: ***
LU WWN Device Id: ***
Firmware Version: PC4OC70D
User Capacity: 500 107 730 944 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Sat Jan 25 20:52:45 2014 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
Read SMART Thresholds failed: scsi error aborted command
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection:
Disabled.
Self-test execution status: ( 0) The previous self-test routine
completed
without error or no self-test has
ever
been run.
Total time to complete Offline
data collection: ( 645) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 131) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control
supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 --- - 0
2 Throughput_Performance P-S--- 100 100 --- - 0
3 Spin_Up_Time POS--- 141 141 --- - 0
4 Start_Stop_Count -O--C- 099 099 --- - 2294
5 Reallocated_Sector_Ct PO--CK 100 100 --- - 0
7 Seek_Error_Rate PO-R-- 100 100 --- - 0
8 Seek_Time_Performance P-S--- 100 100 --- - 0
9 Power_On_Hours -O--C- 087 087 --- - 5863
10 Spin_Retry_Count PO--C- 100 100 --- - 0
12 Power_Cycle_Count -O--CK 099 099 --- - 2103
191 G-Sense_Error_Rate -O-R-- 100 100 --- - 0
192 Power-Off_Retract_Count -O--CK 100 100 --- - 68
193 Load_Cycle_Count -O--C- 071 071 --- - 295951
194 Temperature_Celsius -O---- 203 203 --- - 27 (Min/Max
16/49)
196 Reallocated_Event_Count -O--CK 100 100 --- - 0
197 Current_Pending_Sector -O---K 100 100 --- - 0
198 Offline_Uncorrectable ---R-- 100 100 --- - 0
199 UDMA_CRC_Error_Count -O-R-- 200 200 --- - 0
223 Load_Retry_Count -O-R-- 100 100 --- - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 1 Comprehensive SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00%
3 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 27 Celsius
Power Cycle Min/Max Temperature: 24/27 Celsius
Lifetime Min/Max Temperature: 16/49 Celsius
Lifetime Average Temperature: 36 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 5/60 Celsius
Min/Max Temperature Limit: -40/65 Celsius
Temperature History Size (Index): 478 (189)
Index Estimated Time Temperature Celsius
190 2014-01-25 12:55 25 ******
... ..( 32 skipped). .. ******
223 2014-01-25 13:28 25 ******
224 2014-01-25 13:29 24 *****
225 2014-01-25 13:30 25 ******
226 2014-01-25 13:31 25 ******
227 2014-01-25 13:32 24 *****
228 2014-01-25 13:33 25 ******
229 2014-01-25 13:34 24 *****
... ..( 95 skipped). .. *****
325 2014-01-25 15:10 24 *****
326 2014-01-25 15:11 25 ******
327 2014-01-25 15:12 24 *****
328 2014-01-25 15:13 24 *****
329 2014-01-25 15:14 25 ******
... ..(103 skipped). .. ******
433 2014-01-25 16:58 25 ******
434 2014-01-25 16:59 26 *******
435 2014-01-25 17:00 26 *******
436 2014-01-25 17:01 26 *******
437 2014-01-25 17:02 27 ********
... ..( 4 skipped). .. ********
442 2014-01-25 17:07 27 ********
443 2014-01-25 17:08 28 *********
... ..( 6 skipped). .. *********
450 2014-01-25 17:15 28 *********
451 2014-01-25 17:16 29 **********
... ..( 8 skipped). .. **********
460 2014-01-25 17:25 29 **********
461 2014-01-25 17:26 28 *********
... ..( 2 skipped). .. *********
464 2014-01-25 17:29 28 *********
465 2014-01-25 17:30 27 ********
... ..( 6 skipped). .. ********
472 2014-01-25 17:37 27 ********
473 2014-01-25 17:38 26 *******
... ..( 11 skipped). .. *******
7 2014-01-25 17:50 26 *******
8 2014-01-25 17:51 25 ******
... ..( 32 skipped). .. ******
41 2014-01-25 18:24 25 ******
42 2014-01-25 18:25 26 *******
43 2014-01-25 18:26 26 *******
44 2014-01-25 18:27 27 ********
... ..( 3 skipped). .. ********
48 2014-01-25 18:31 27 ********
49 2014-01-25 18:32 28 *********
... ..( 4 skipped). .. *********
54 2014-01-25 18:37 28 *********
55 2014-01-25 18:38 29 **********
... ..( 7 skipped). .. **********
63 2014-01-25 18:46 29 **********
64 2014-01-25 18:47 28 *********
... ..( 4 skipped). .. *********
69 2014-01-25 18:52 28 *********
70 2014-01-25 18:53 27 ********
... ..( 96 skipped). .. ********
167 2014-01-25 20:30 27 ********
168 2014-01-25 20:31 28 *********
... ..( 2 skipped). .. *********
171 2014-01-25 20:34 28 *********
172 2014-01-25 20:35 29 **********
... ..( 5 skipped). .. **********
178 2014-01-25 20:41 29 **********
179 2014-01-25 20:42 30 ***********
180 2014-01-25 20:43 30 ***********
181 2014-01-25 20:44 30 ***********
182 2014-01-25 20:45 23 ****
183 2014-01-25 20:46 24 *****
184 2014-01-25 20:47 25 ******
185 2014-01-25 20:48 25 ******
186 2014-01-25 20:49 26 *******
187 2014-01-25 20:50 26 *******
188 2014-01-25 20:51 27 ********
189 2014-01-25 20:52 27 ********
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP Log 0x04) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
------------------------------------------------------------------------------
CenturyLink Cloud: The Leader in Enterprise Cloud Services.
Learn Why More Businesses Are Choosing CenturyLink Cloud For
Critical Workloads, Development Environments & Everything In Between.
Get a Quote or Start a Free Trial Today.
http://pubads.g.doubleclick.net/gampad/clk?id=119420431&iu=/4140/ostg.clktrk
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net