SSD is not in smartctl database.

smartctl 6.3 2014-07-26 r3976 [i686-w64-mingw32-win7(64)-sp1] (sf-6.3-1)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     PLEXTOR PX-128M6S
Serial Number:    P02438113594
LU WWN Device Id: 5 002303 1002c4837
Add. Product Id:  HC7020E0
Firmware Version: 1.03
User Capacity:    128 035 676 160 bytes [128 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ATA8-ACS, ATA/ATAPI-7 T13/1532D revision 4a
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Mon Nov 10 23:52:32 2014
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM feature is:   Unavailable
Rd look-ahead is: Enabled
Write cache is:   Enabled
ATA Security is:  Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine
completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (   10) seconds.
Offline data collection
capabilities:  (0x15) SMART execute Offline immediate.
No Auto Offline data collection support.
Abort Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time:  (   1) minutes.
Extended self-test routine
recommended polling time:  (  10) minutes.
SCT capabilities:        (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED
 WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   100   100   000    Pre-fail  Always
    -       0
  5 Reallocated_Sector_Ct   0x0003   100   100   000    Pre-fail  Always
    -       0
  9 Power_On_Hours          0x0002   100   100   000    Old_age   Always
    -       5
 12 Power_Cycle_Count       0x0003   100   100   000    Pre-fail  Always
    -       36
170 Unknown_Attribute       0x0032   100   100   000    Old_age   Always
    -       0
171 Unknown_Attribute       0x0003   100   100   000    Pre-fail  Always
    -       0
172 Unknown_Attribute       0x0003   100   100   000    Pre-fail  Always
    -       0
173 Unknown_Attribute       0x0003   100   100   000    Pre-fail  Always
    -       1193
174 Unknown_Attribute       0x0003   100   100   000    Pre-fail  Always
    -       2
175 Program_Fail_Count_Chip 0x0003   100   100   000    Pre-fail  Always
    -       0
176 Erase_Fail_Count_Chip   0x0003   100   100   000    Pre-fail  Always
    -       0
177 Wear_Leveling_Count     0x0003   100   100   000    Pre-fail  Always
    -       1193
178 Used_Rsvd_Blk_Cnt_Chip  0x0003   100   100   000    Pre-fail  Always
    -       0
179 Used_Rsvd_Blk_Cnt_Tot   0x0003   100   100   000    Pre-fail  Always
    -       0
180 Unused_Rsvd_Blk_Cnt_Tot 0x0033   100   100   000    Pre-fail  Always
    -       960
181 Program_Fail_Cnt_Total  0x0003   100   100   000    Pre-fail  Always
    -       0
182 Erase_Fail_Count_Total  0x0003   100   100   000    Pre-fail  Always
    -       0
183 Runtime_Bad_Block       0x0032   100   100   000    Old_age   Always
    -       0
184 End-to-End_Error        0x0033   100   100   000    Pre-fail  Always
    -       0
187 Reported_Uncorrect      0x0003   100   100   000    Pre-fail  Always
    -       0
188 Command_Timeout         0x0032   100   100   000    Old_age   Always
    -       0
192 Power-Off_Retract_Count 0x0003   100   100   000    Pre-fail  Always
    -       2
195 Hardware_ECC_Recovered  0x0003   100   100   000    Pre-fail  Always
    -       0
196 Reallocated_Event_Count 0x0003   100   100   000    Pre-fail  Always
    -       0
198 Offline_Uncorrectable   0x0003   100   100   000    Pre-fail  Always
    -       0
199 UDMA_CRC_Error_Count    0x0003   100   100   000    Pre-fail  Always
    -       0
232 Available_Reservd_Space 0x0003   100   100   010    Pre-fail  Always
    -       0
233 Media_Wearout_Indicator 0x0003   100   100   000    Pre-fail  Always
    -       74
241 Total_LBAs_Written      0x0003   100   100   000    Pre-fail  Always
    -       3864
242 Total_LBAs_Read         0x0003   100   100   000    Pre-fail  Always
    -       3220

SMART Error Log Version: 0
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

Selective Self-tests/Logging not supported



-- 
dam...@damianek.be
------------------------------------------------------------------------------
Comprehensive Server Monitoring with Site24x7.
Monitor 10 servers for $9/Month.
Get alerted through email, SMS, voice calls or mobile push notifications.
Take corrective actions from your mobile device.
http://pubads.g.doubleclick.net/gampad/clk?id=154624111&iu=/4140/ostg.clktrk
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to