smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-4-amd64] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: WDC WD40EFRX-68WT0N0
Firmware Version: 82.00A82
User Capacity: 4,000,787,030,016 bytes [4.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 9
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Fri Dec 26 12:32:49 2014 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (52080) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 255) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x703d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 177 176 021 - 8108
4 Start_Stop_Count -O--CK 100 100 000 - 34
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 099 099 000 - 957
10 Spin_Retry_Count -O--CK 100 253 000 - 0
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 34
192 Power-Off_Retract_Count -O--CK 200 200 000 - 18
193 Load_Cycle_Count -O--CK 200 200 000 - 932
194 Temperature_Celsius -O---K 122 101 000 - 30
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 200 200 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
GP/S Log at address 0x00 has 1 sectors [Log Directory]
SMART Log at address 0x01 has 1 sectors [Summary SMART error log]
SMART Log at address 0x02 has 5 sectors [Comprehensive SMART error log]
GP Log at address 0x03 has 6 sectors [Ext. Comprehensive SMART error log]
SMART Log at address 0x06 has 1 sectors [SMART self-test log]
GP Log at address 0x07 has 1 sectors [Extended self-test log]
SMART Log at address 0x09 has 1 sectors [Selective self-test log]
GP Log at address 0x10 has 1 sectors [NCQ Command Error]
GP Log at address 0x11 has 1 sectors [SATA Phy Event Counters]
GP Log at address 0x21 has 1 sectors [Write stream error log]
GP Log at address 0x22 has 1 sectors [Read stream error log]
GP/S Log at address 0x80 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x81 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x82 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x83 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x84 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x85 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x86 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x87 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x88 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x89 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x8a has 16 sectors [Host vendor specific log]
GP/S Log at address 0x8b has 16 sectors [Host vendor specific log]
GP/S Log at address 0x8c has 16 sectors [Host vendor specific log]
GP/S Log at address 0x8d has 16 sectors [Host vendor specific log]
GP/S Log at address 0x8e has 16 sectors [Host vendor specific log]
GP/S Log at address 0x8f has 16 sectors [Host vendor specific log]
GP/S Log at address 0x90 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x91 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x92 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x93 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x94 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x95 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x96 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x97 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x98 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x99 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x9a has 16 sectors [Host vendor specific log]
GP/S Log at address 0x9b has 16 sectors [Host vendor specific log]
GP/S Log at address 0x9c has 16 sectors [Host vendor specific log]
GP/S Log at address 0x9d has 16 sectors [Host vendor specific log]
GP/S Log at address 0x9e has 16 sectors [Host vendor specific log]
GP/S Log at address 0x9f has 16 sectors [Host vendor specific log]
GP/S Log at address 0xa0 has 16 sectors [Device vendor specific log]
GP/S Log at address 0xa1 has 16 sectors [Device vendor specific log]
GP/S Log at address 0xa2 has 16 sectors [Device vendor specific log]
GP/S Log at address 0xa3 has 16 sectors [Device vendor specific log]
GP/S Log at address 0xa4 has 16 sectors [Device vendor specific log]
GP/S Log at address 0xa5 has 16 sectors [Device vendor specific log]
GP/S Log at address 0xa6 has 16 sectors [Device vendor specific log]
GP/S Log at address 0xa7 has 16 sectors [Device vendor specific log]
GP/S Log at address 0xa8 has 1 sectors [Device vendor specific log]
GP/S Log at address 0xa9 has 1 sectors [Device vendor specific log]
GP/S Log at address 0xaa has 1 sectors [Device vendor specific log]
GP/S Log at address 0xab has 1 sectors [Device vendor specific log]
GP/S Log at address 0xac has 1 sectors [Device vendor specific log]
GP/S Log at address 0xad has 1 sectors [Device vendor specific log]
GP/S Log at address 0xae has 1 sectors [Device vendor specific log]
GP/S Log at address 0xaf has 1 sectors [Device vendor specific log]
GP/S Log at address 0xb0 has 1 sectors [Device vendor specific log]
GP/S Log at address 0xb1 has 1 sectors [Device vendor specific log]
GP/S Log at address 0xb2 has 1 sectors [Device vendor specific log]
GP/S Log at address 0xb3 has 1 sectors [Device vendor specific log]
GP/S Log at address 0xb4 has 1 sectors [Device vendor specific log]
GP/S Log at address 0xb5 has 1 sectors [Device vendor specific log]
GP/S Log at address 0xb6 has 1 sectors [Device vendor specific log]
GP/S Log at address 0xb7 has 1 sectors [Device vendor specific log]
GP/S Log at address 0xbd has 1 sectors [Device vendor specific log]
GP/S Log at address 0xc0 has 1 sectors [Device vendor specific log]
GP Log at address 0xc1 has 93 sectors [Device vendor specific log]
GP/S Log at address 0xe0 has 1 sectors [SCT Command/Status]
GP/S Log at address 0xe1 has 1 sectors [SCT Data Transfer]
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
Device Error Count: 3
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 3 [2] occurred at disk power-on lifetime: 356 hours (14 days + 20 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 01 00 00 00 00 00 00 00 00 Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 d5 00 01 00 00 00 c2 4f e1 00 08 00:06:26.211 SMART READ LOG
b0 00 d5 00 01 00 00 00 c2 4f e1 00 08 00:06:26.211 SMART READ LOG
b0 00 d5 00 01 00 00 00 c2 4f e0 00 08 00:06:26.211 SMART READ LOG
b0 00 d6 00 01 00 00 00 c2 4f e0 00 08 00:06:26.210 SMART WRITE LOG
b0 00 d6 00 01 00 00 00 c2 4f e0 00 08 00:06:26.209 SMART WRITE LOG
Error 2 [1] occurred at disk power-on lifetime: 355 hours (14 days + 19 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 01 00 00 00 00 00 00 00 00 Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 d5 00 01 00 00 00 c2 4f e1 00 08 00:12:32.076 SMART READ LOG
b0 00 d6 00 01 00 00 00 c2 4f e0 00 08 00:12:32.076 SMART WRITE LOG
b0 00 d5 00 01 00 00 00 c2 4f e0 00 08 00:12:32.076 SMART READ LOG
b0 00 d6 00 01 00 00 00 c2 4f e0 00 08 00:12:32.075 SMART WRITE LOG
b0 00 d5 00 01 00 00 00 c2 4f e0 00 08 00:12:32.075 SMART READ LOG
Error 1 [0] occurred at disk power-on lifetime: 355 hours (14 days + 19 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 01 00 00 00 00 00 00 00 00 Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 d5 00 01 00 00 00 c2 4f e1 00 08 00:12:32.075 SMART READ LOG
b0 00 d5 00 01 00 00 00 c2 4f e1 00 08 00:12:32.074 SMART READ LOG
b0 00 d5 00 01 00 00 00 c2 4f 09 00 08 00:12:32.074 SMART READ LOG
b0 00 d6 00 01 00 00 00 c2 4f e0 00 08 00:12:32.073 SMART WRITE LOG
b0 00 d6 00 01 00 00 00 c2 4f e0 00 08 00:12:32.072 SMART WRITE LOG
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 956 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 30 Celsius
Power Cycle Min/Max Temperature: 24/32 Celsius
Lifetime Min/Max Temperature: 23/50 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (74)
Index Estimated Time Temperature Celsius
75 2014-12-26 04:35 28 *********
... ..(273 skipped). .. *********
349 2014-12-26 09:09 28 *********
350 2014-12-26 09:10 29 **********
... ..(158 skipped). .. **********
31 2014-12-26 11:49 29 **********
32 2014-12-26 11:50 30 ***********
... ..( 41 skipped). .. ***********
74 2014-12-26 12:32 30 ***********
SCT Error Recovery Control:
Read: 70 (7.0 seconds)
Write: 70 (7.0 seconds)
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 420835 Vendor specific
------------------------------------------------------------------------------
Dive into the World of Parallel Programming! The Go Parallel Website,
sponsored by Intel and developed in partnership with Slashdot Media, is your
hub for all things parallel software development, from weekly thought
leadership blogs to news, videos, case studies, tutorials and more. Take a
look and join the conversation now. http://goparallel.sourceforge.net
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database