smartctl 6.0 2012-10-10 r3643 [x86_64-linux-3.0.101-0.29-default] (SUSE RPM)
Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: MM0500GBKAK
Firmware Version: HPGC
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Mon Jan 12 14:42:49 2015 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Disabled
ATA Security is: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 642) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 103) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x103d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 082 063 044 - 174059297
3 Spin_Up_Time PO---- 096 096 070 - 0
4 Start_Stop_Count -O--CK 100 100 020 - 33
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
7 Seek_Error_Rate POSR-- 078 060 030 - 65023078
9 Power_On_Hours -O--CK 091 091 000 - 7921
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 100 100 020 - 33
180 Unknown_HDD_Attribute PO-RCK 100 100 030 - 241663
184 End-to-End_Error -O--CK 100 100 003 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
188 Command_Timeout -O--CK 100 100 000 - 0
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 076 072 045 - 24 (Min/Max 22/28)
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
192 Power-Off_Retract_Count -O--CK 100 100 000 - 31
193 Load_Cycle_Count -O--CK 100 100 000 - 360
194 Temperature_Celsius -O---K 024 040 000 - 24 (0 16 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 118 099 000 - 174059297
196 Reallocated_Event_Count PO--CK 100 100 036 - 0
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
GP/S Log at address 0x00 has 1 sectors [Log Directory]
SMART Log at address 0x01 has 1 sectors [Summary SMART error log]
SMART Log at address 0x02 has 5 sectors [Comprehensive SMART error log]
GP Log at address 0x03 has 5 sectors [Ext. Comprehensive SMART error log]
GP/S Log at address 0x04 has 8 sectors [Device Statistics log]
SMART Log at address 0x06 has 1 sectors [SMART self-test log]
GP Log at address 0x07 has 1 sectors [Extended self-test log]
SMART Log at address 0x09 has 1 sectors [Selective self-test log]
GP Log at address 0x10 has 1 sectors [NCQ Command Error log]
GP Log at address 0x11 has 1 sectors [SATA Phy Event Counters]
GP/S Log at address 0x12 has 1 sectors [SATA NCQ Queue Management log]
GP Log at address 0x21 has 1 sectors [Write stream error log]
GP Log at address 0x22 has 1 sectors [Read stream error log]
GP/S Log at address 0x80 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x81 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x82 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x83 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x84 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x85 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x86 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x87 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x88 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x89 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x8a has 16 sectors [Host vendor specific log]
GP/S Log at address 0x8b has 16 sectors [Host vendor specific log]
GP/S Log at address 0x8c has 16 sectors [Host vendor specific log]
GP/S Log at address 0x8d has 16 sectors [Host vendor specific log]
GP/S Log at address 0x8e has 16 sectors [Host vendor specific log]
GP/S Log at address 0x8f has 16 sectors [Host vendor specific log]
GP/S Log at address 0x90 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x91 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x92 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x93 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x94 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x95 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x96 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x97 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x98 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x99 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x9a has 16 sectors [Host vendor specific log]
GP/S Log at address 0x9b has 16 sectors [Host vendor specific log]
GP/S Log at address 0x9c has 16 sectors [Host vendor specific log]
GP/S Log at address 0x9d has 16 sectors [Host vendor specific log]
GP/S Log at address 0x9e has 16 sectors [Host vendor specific log]
GP/S Log at address 0x9f has 16 sectors [Host vendor specific log]
GP/S Log at address 0xa1 has 20 sectors [Device vendor specific log]
GP Log at address 0xa2 has 4496 sectors [Device vendor specific log]
GP/S Log at address 0xa8 has 129 sectors [Device vendor specific log]
GP/S Log at address 0xa9 has 1 sectors [Device vendor specific log]
GP Log at address 0xb0 has 5176 sectors [Device vendor specific log]
GP Log at address 0xb6 has 1918 sectors [Device vendor specific log]
GP Log at address 0xbd has 252 sectors [Device vendor specific log]
GP Log at address 0xbe has 65535 sectors [Device vendor specific log]
GP Log at address 0xbf has 65535 sectors [Device vendor specific log]
GP/S Log at address 0xe0 has 1 sectors [SCT Command/Status]
GP/S Log at address 0xe1 has 1 sectors [SCT Data Transfer]
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 7921 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 522 (0x020a)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 25 Celsius
Power Cycle Min/Max Temperature: 22/28 Celsius
Lifetime Min/Max Temperature: 16/51 Celsius
Under/Over Temperature Limit Count: 0/35563
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/ 0 Celsius
Min/Max Temperature Limit: 0/ 0 Celsius
Temperature History Size (Index): 128 (18)
Index Estimated Time Temperature Celsius
19 2015-01-11 17:30 25 ******
... ..( 15 skipped). .. ******
35 2015-01-11 20:10 25 ******
36 2015-01-11 20:20 24 *****
... ..( 56 skipped). .. *****
93 2015-01-12 05:50 24 *****
94 2015-01-12 06:00 25 ******
95 2015-01-12 06:10 25 ******
96 2015-01-12 06:20 25 ******
97 2015-01-12 06:30 24 *****
... ..( 2 skipped). .. *****
100 2015-01-12 07:00 24 *****
101 2015-01-12 07:10 25 ******
102 2015-01-12 07:20 24 *****
... ..( 5 skipped). .. *****
108 2015-01-12 08:20 24 *****
109 2015-01-12 08:30 25 ******
110 2015-01-12 08:40 24 *****
... ..( 7 skipped). .. *****
118 2015-01-12 10:00 24 *****
119 2015-01-12 10:10 25 ******
120 2015-01-12 10:20 24 *****
... ..( 5 skipped). .. *****
126 2015-01-12 11:20 24 *****
127 2015-01-12 11:30 25 ******
0 2015-01-12 11:40 24 *****
... ..( 11 skipped). .. *****
12 2015-01-12 13:40 24 *****
13 2015-01-12 13:50 25 ******
14 2015-01-12 14:00 25 ******
15 2015-01-12 14:10 25 ******
16 2015-01-12 14:20 24 *****
17 2015-01-12 14:30 24 *****
18 2015-01-12 14:40 24 *****
SCT Error Recovery Control:
Read: 100 (10.0 seconds)
Write: 100 (10.0 seconds)
Device Statistics (GP Log 0x04)
Page Offset Size Value Description
1 ===== = = == General Statistics (rev 2) ==
1 0x008 4 33 Lifetime Power-On Resets
1 0x010 4 7921 Power-on Hours
1 0x018 6 2332447698 Logical Sectors Written
1 0x020 6 74980518 Number of Write Commands
1 0x028 6 531211901 Logical Sectors Read
1 0x030 6 7430950 Number of Read Commands
3 ===== = = == Rotating Media Statistics (rev 1) ==
3 0x008 4 7928 Spindle Motor Power-on Hours
3 0x010 4 7928 Head Flying Hours
3 0x018 4 360 Head Load Events
3 0x020 4 0 Number of Reallocated Logical Sectors
3 0x028 4 0 Read Recovery Attempts
3 0x030 4 0 Number of Mechanical Start Failures
4 ===== = = == General Errors Statistics (rev 1) ==
4 0x008 4 0 Number of Reported Uncorrectable Errors
4 0x010 4 0 Resets Between Cmd Acceptance and Completion
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 13 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
------------------------------------------------------------------------------
New Year. New Location. New Benefits. New Data Center in Ashburn, VA.
GigeNET is offering a free month of service with a new server in Ashburn.
Choose from 2 high performing configs, both with 100TB of bandwidth.
Higher redundancy.Lower latency.Increased capacity.Completely compliant.
http://p.sf.net/sfu/gigenet
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database