The device model INTEL SSDSC2BG200G4R is also known as Intel SSD DC
S3610 Series, please add the correct Model Family and the SMART
attributes to the smartdb.

Attached you find the
* smartctl -a output

Here is the model number from an idsct output (an intel datacenter ssd
toolbox)
* $ sudo isdct show -all -intelssd
   [...]
   ProductFamily: Intel SSD DC S3610 Series
   ModelNumber: INTEL SSDSC2BG200G4R

I am also adding a link to the specification of the SMART attributes:
*http://www.intel.com/content/dam/www/public/us/en/documents/product-specifications/ssd-dc-s3610-spec.pdf

Thanks, Georg


$ sudo smartctl -a /dev/sda
smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.13.0-49-generic] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     INTEL SSDSC2BG200G4R
Serial Number:    BTHC5112049M200TGN
LU WWN Device Id: 5 5cd2e4 04b7ac353
Add. Product Id:  DELL(tm)
Firmware Version: G201DL20
User Capacity:    200,049,647,616 bytes [200 GB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    Solid State Device
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-2 T13/2015-D revision 3
SATA Version is:  SATA 2.6, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Wed Apr 29 12:00:08 2015 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                (    0) seconds.
Offline data collection
capabilities:                    (0x79) SMART execute Offline immediate.
                                        No Auto Offline data collection support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (  60) minutes.
Conveyance self-test routine
recommended polling time:        (  60) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000e   130   130   039    Old_age   Always       
-       1483
  5 Reallocated_Sector_Ct   0x0033   100   100   001    Pre-fail  Always       
-       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       
-       645
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       11
 13 Read_Soft_Error_Rate    0x001e   130   100   000    Old_age   Always       
-       1483
179 Used_Rsvd_Blk_Cnt_Tot   0x0033   100   100   010    Pre-fail  Always       
-       0
180 Unused_Rsvd_Blk_Cnt_Tot 0x0032   100   100   000    Old_age   Always       
-       5447
181 Program_Fail_Cnt_Total  0x003a   100   100   000    Old_age   Always       
-       0
182 Erase_Fail_Count_Total  0x003a   100   100   000    Old_age   Always       
-       0
184 End-to-End_Error        0x0032   100   100   000    Old_age   Always       
-       0
194 Temperature_Celsius     0x0022   100   100   000    Old_age   Always       
-       36
195 Hardware_ECC_Recovered  0x0032   100   100   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x003e   100   100   000    Old_age   Always       
-       0
201 Unknown_SSD_Attribute   0x0033   100   100   010    Pre-fail  Always       
-       17181446958
202 Unknown_SSD_Attribute   0x0027   100   100   000    Pre-fail  Always       
-       0
226 Unknown_SSD_Attribute   0x0032   100   100   000    Old_age   Always       
-       0
227 Unknown_SSD_Attribute   0x0032   100   100   000    Old_age   Always       
-       100
228 Power-off_Retract_Count 0x0032   100   100   000    Old_age   Always       
-       38651
233 Media_Wearout_Indicator 0x0032   100   100   000    Old_age   Always       
-       1631
245 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       
-       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
===================================================================================================================
------------------------------------------------------------------------------
One dashboard for servers and applications across Physical-Virtual-Cloud 
Widest out-of-the-box monitoring support with 50+ applications
Performance metrics, stats and reports that give you Actionable Insights
Deep dive visibility with transaction tracing using APM Insight.
http://ad.doubleclick.net/ddm/clk/290420510;117567292;y
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to