Hi,

I can see OCZ Trion 100[1] is missing in the database.  Here comes drive info
and a tentative patch.  Attribute names in the patch come from OCZ's SSD Guru
tool.  I'd be glad to see the drive supported by smartmontools.

Libor

[1] 
http://ocz.com/consumer/company/newsroom/press/ocz-releases-value-oriented-trion-100-ssd-series-with-premium-toshiba-tlc-nand-flash
smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.16.0-4-amd64] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     OCZ-TRION100
Device Model:     OCZ-TRION100
Serial Number:    555B60AOKMBX
LU WWN Device Id: 5 e83a97 20022e96c
Firmware Version: SAFM11.1
User Capacity:    120,034,123,776 bytes [120 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Form Factor:      2.5 inches
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ACS-2 (minor revision not indicated)
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is:    Thu Aug 13 21:33:50 2015 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM level is:     254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is:   Enabled
ATA Security is:  Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                (   30) seconds.
Offline data collection
capabilities:                    (0x79) SMART execute Offline immediate.
                                        No Auto Offline data collection support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (   2) minutes.
Conveyance self-test routine
recommended polling time:        (   3) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  9 Power_On_Hours          -O--C-   100   100   000    -    7
 12 Power_Cycle_Count       -O--C-   100   100   000    -    8
167 SSD_Protect_Mode        -O---K   100   100   000    -    0
168 SATA_PHY_Error_Count    -O--C-   100   100   000    -    0
169 Total_Bad_Block_Count   PO----   100   100   010    -    0
173 Erase_Count             -O--C-   200   200   000    -    0
192 Power-Off_Retract_Count -O--C-   100   100   000    -    4
194 Temperature_Celsius     PO---K   060   041   030    -    40 (Min/Max 24/59)
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 1
SMART           Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00       GPL,SL  R/O      1  Log Directory
0x01           SL  R/O      1  Summary SMART error log
0x02           SL  R/O     51  Comprehensive SMART error log
0x03       GPL     R/O     64  Ext. Comprehensive SMART error log
0x04       GPL,SL  R/O      8  Device Statistics log
0x06           SL  R/O      1  SMART self-test log
0x07       GPL     R/O      1  Extended self-test log
0x09           SL  R/W      1  Selective self-test log
0x10       GPL     R/O      1  SATA NCQ Queued Error log
0x11       GPL     R/O      1  SATA Phy Event Counters log
0x30       GPL,SL  R/O      9  IDENTIFY DEVICE data log
0x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
0xe0       GPL,SL  R/W      1  SCT Command/Status
0xe1       GPL,SL  R/W      1  SCT Data Transfer

SMART Extended Comprehensive Error Log Version: 1 (64 sectors)
No Errors Logged

SMART Extended Self-test Log Version: 1 (1 sectors)
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%         7         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Commands not supported

Device Statistics (GP Log 0x04)
Page Offset Size         Value  Description
  1  =====  =                =  == General Statistics (rev 2) ==
  1  0x008  4                8  Lifetime Power-On Resets
  1  0x010  4                7  Power-on Hours
  1  0x018  6        201301304  Logical Sectors Written
  1  0x020  6           269297  Number of Write Commands
  1  0x028  6        125534326  Logical Sectors Read
  1  0x030  6          4725345  Number of Read Commands
  1  0x038  6         25742755  Date and Time TimeStamp
  4  =====  =                =  == General Errors Statistics (rev 1) ==
  4  0x008  4                0  Number of Reported Uncorrectable Errors
  4  0x010  4                0  Resets Between Cmd Acceptance and Completion
  5  =====  =                =  == Temperature Statistics (rev 1) ==
  5  0x008  1               32  Current Temperature
  5  0x010  1               32  Average Short Term Temperature
  5  0x018  1               32  Average Long Term Temperature
  5  0x020  1               50  Highest Temperature
  5  0x028  1                5  Lowest Temperature
  5  0x030  1               50  Highest Average Short Term Temperature
  5  0x038  1               16  Lowest Average Short Term Temperature
  5  0x040  1               50  Highest Average Long Term Temperature
  5  0x048  1               16  Lowest Average Long Term Temperature
  5  0x050  4                0  Time in Over-Temperature
  5  0x058  1               50  Specified Maximum Operating Temperature
  5  0x060  4                0  Time in Under-Temperature
  5  0x068  1                5  Specified Minimum Operating Temperature
  6  =====  =                =  == Transport Statistics (rev 1) ==
  6  0x008  4                5  Number of Hardware Resets
  6  0x018  4                0  Number of Interface CRC Errors
  7  =====  =                =  == Solid State Device Statistics (rev 1) ==
  7  0x008  1                0  Percentage Used Endurance Indicator

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x0001  2            0  Command failed due to ICRC error
0x0003  2            0  R_ERR response for device-to-host data FIS
0x0004  2            0  R_ERR response for host-to-device data FIS
0x0006  2            0  R_ERR response for device-to-host non-data FIS
0x0007  2            0  R_ERR response for host-to-device non-data FIS
0x0008  2            0  Device-to-host non-data FIS retries
0x0009  4            5  Transition from drive PhyRdy to drive PhyNRdy
0x000a  4           12  Device-to-host register FISes sent due to a COMRESET
0x000f  2            0  R_ERR response for host-to-device data FIS, CRC
0x0010  2            0  R_ERR response for host-to-device data FIS, non-CRC
0x0012  2            0  R_ERR response for host-to-device non-data FIS, CRC
0x0013  2            0  R_ERR response for host-to-device non-data FIS, non-CRC

--- /var/lib/smartmontools/drivedb/drivedb.h.orig	2015-08-13 21:10:58.918655953 +0200
+++ /var/lib/smartmontools/drivedb/drivedb.h	2015-08-13 21:18:49.882678575 +0200
@@ -545,6 +545,14 @@
     "-v 249,raw48,Total_NAND_Prog_Ct_GiB "
     "-v 251,raw48,Total_NAND_Read_Ct_GiB"
   },
+  { "OCZ-TRION100",
+    "OCZ-TRION100",
+    "", "",
+    "-v 167,raw48,SSD_Protect_Mode "
+    "-v 168,raw48,SATA_PHY_Error_Count "
+    "-v 169,raw48,Total_Bad_Block_Count "
+    "-v 173,raw48,Erase_Count "
+  },
   { "InnoDisk InnoLite SATADOM D150QV-L SSDs", // tested with InnoLite SATADOM D150QV-L/120319
     "InnoLite SATADOM D150QV-L",
     "", "",
------------------------------------------------------------------------------
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database