Please add ST120HM000-1G5142 to the DB or let me know if I need to do anything 
else or submit this to a different e-mail.

Thanks,

Liz Swaffield
Associate Software Engineer
Electrosonic Inc.

Tel +1 818.333.7683 | Mobile +1 818.434.8844
3320 North San Fernando Blvd., Burbank, CA, 91504 - USA
liz.swaffi...@electrosonic.com<mailto:liz.swaffi...@electrosonic.com> | 
www.electrosonic.com<http://www.electrosonic.com>
smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.13.0-63-generic] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     ST120HM000-1G5142
Serial Number:    Z4M00TYV
LU WWN Device Id: 5 000c50 02ff325f2
Firmware Version: C675
User Capacity:    120,034,123,776 bytes [120 GB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    Solid State Device
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ATA8-ACS T13/1699-D revision 4
SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is:    Tue Sep  8 16:58:40 2015 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM feature is:   Unavailable
Rd look-ahead is: Enabled
Write cache is:   Enabled
ATA Security is:  Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x02) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                (    3) seconds.
Offline data collection
capabilities:                    (0x19) SMART execute Offline immediate.
                                        No Auto Offline data collection support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        No Selective Self-test supported.
SMART capabilities:            (0x0002) Does not save SMART data before
                                        entering power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (  19) minutes.

SMART Attributes Data Structure revision number: 0
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     -OSR--   166   166   006    -    0
  5 Reallocated_Sector_Ct   PO--CK   100   100   036    -    0
  9 Power_On_Hours          -O--CK   100   100   000    -    11
 12 Power_Cycle_Count       -O--CK   100   100   020    -    11
171 Unknown_Attribute       -O--CK   100   100   000    -    0
172 Unknown_Attribute       -O--CK   100   100   000    -    0
181 Program_Fail_Cnt_Total  -O--CK   100   100   000    -    0
182 Erase_Fail_Count_Total  -O--CK   100   100   000    -    0
194 Temperature_Celsius     -O---K   032   026   000    -    32 (Min/Max 23/56)
201 Unknown_SSD_Attribute   -O--CK   100   100   000    -    0
204 Soft_ECC_Correction     -O--CK   100   100   000    -    0
231 Temperature_Celsius     PO--C-   100   100   010    -    0
234 Unknown_Attribute       -O--CK   100   100   000    -    95
241 Total_LBAs_Written      -O--CK   100   100   000    -    89
242 Total_LBAs_Read         -O--CK   100   100   000    -    2
250 Read_Error_Retry_Rate   -O--CK   100   100   000    -    0
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 1
SMART           Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00       GPL,SL  R/O      1  Log Directory
0x03       GPL,SL  R/O      5  Ext. Comprehensive SMART error log
0x04       GPL,SL  R/O      8  Device Statistics log
0x07       GPL,SL  R/O      2  Extended self-test log
0x10       GPL     R/O      1  NCQ Command Error log
0x11       GPL     R/O      1  SATA Phy Event Counters
0x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
0xa8       GPL     VS     521  Device vendor specific log
0xa8       SL      VS     255  Device vendor specific log
0xb7       GPL,SL  VS       4  Device vendor specific log

SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
Device Error Count: 28 (device log contains only the most recent 20 errors)
        CR     = Command Register
        FEATR  = Features Register
        COUNT  = Count (was: Sector Count) Register
        LBA_48 = Upper bytes of LBA High/Mid/Low Registers ]  ATA-8
        LH     = LBA High (was: Cylinder High) Register    ]   LBA
        LM     = LBA Mid (was: Cylinder Low) Register      ] Register
        LL     = LBA Low (was: Sector Number) Register     ]
        DV     = Device (was: Device/Head) Register
        DC     = Device Control Register
        ER     = Error register
        ST     = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 28 [7] occurred at disk power-on lifetime: 10 hours (0 days + 10 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  04 -- 51 00 fe 00 00 00 00 00 00 40 08  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  ef 00 05 00 fe 00 00 00 00 00 00 40 08     01:07:04.810  SET FEATURES [Enable 
APM]
  60 00 08 00 c8 00 00 09 04 0b 30 40 08     01:07:04.790  READ FPDMA QUEUED
  60 00 08 00 c0 00 00 09 04 11 e8 40 08     01:07:04.780  READ FPDMA QUEUED
  60 00 08 00 b8 00 00 09 04 0f 48 40 08     01:07:04.780  READ FPDMA QUEUED
  60 00 08 00 b0 00 00 09 04 09 a8 40 08     01:07:04.780  READ FPDMA QUEUED

Error 27 [6] occurred at disk power-on lifetime: 10 hours (0 days + 10 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  04 -- 51 10 45 00 00 00 00 00 00 e0 00  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  b0 00 d2 00 f1 00 00 00 c2 4f 00 00 00     01:06:51.780  SMART ENABLE/DISABLE 
ATTRIBUTE AUTOSAVE
  ec 03 00 45 00 00 00 00 00 00 00 00 00     01:06:51.780  IDENTIFY DEVICE
  ef 00 03 10 45 00 00 00 00 00 00 00 00     01:06:51.780  SET FEATURES [Set 
transfer mode]
  c6 03 00 0c 10 00 00 00 00 00 00 00 00     01:06:51.780  SET MULTIPLE MODE
  ef 00 03 01 0c 00 00 00 00 00 00 00 00     01:06:51.780  SET FEATURES [Set 
transfer mode]

Error 26 [5] occurred at disk power-on lifetime: 10 hours (0 days + 10 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  04 -- 51 00 fe 00 00 00 00 00 00 40 08  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  ef 00 05 00 fe 00 00 00 00 00 00 40 08     00:56:24.000  SET FEATURES [Enable 
APM]
  60 00 08 00 00 00 00 01 c4 0a a8 40 08     00:56:23.990  READ FPDMA QUEUED
  60 00 08 00 f0 00 00 00 00 10 00 40 08     00:56:23.940  READ FPDMA QUEUED
  60 00 08 00 e8 00 00 00 00 00 20 40 08     00:56:23.940  READ FPDMA QUEUED
  60 00 08 00 e0 00 00 00 00 02 00 40 08     00:56:23.940  READ FPDMA QUEUED

Error 25 [4] occurred at disk power-on lifetime: 10 hours (0 days + 10 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  04 -- 51 10 45 00 00 00 00 00 00 e0 00  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  b0 00 d2 00 f1 00 00 00 c2 4f 00 00 00     00:56:10.990  SMART ENABLE/DISABLE 
ATTRIBUTE AUTOSAVE
  ec 03 00 45 00 00 00 00 00 00 00 00 00     00:56:10.990  IDENTIFY DEVICE
  ef 00 03 10 45 00 00 00 00 00 00 00 00     00:56:10.990  SET FEATURES [Set 
transfer mode]
  c6 03 00 0c 10 00 00 00 00 00 00 00 00     00:56:10.990  SET MULTIPLE MODE
  ef 00 03 01 0c 00 00 00 00 00 00 00 00     00:56:10.990  SET FEATURES [Set 
transfer mode]

Error 24 [3] occurred at disk power-on lifetime: 9 hours (0 days + 9 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  04 -- 51 00 fe 00 00 00 00 00 00 40 08  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  ef 00 05 00 fe 00 00 00 00 00 00 40 08     00:00:16.750  SET FEATURES [Enable 
APM]
  60 00 20 00 e8 00 00 0c c4 45 00 40 08     00:00:16.750  READ FPDMA QUEUED
  60 00 08 00 e0 00 00 09 07 f8 08 40 08     00:00:16.740  READ FPDMA QUEUED
  60 00 20 00 d8 00 00 00 14 73 20 40 08     00:00:16.740  READ FPDMA QUEUED
  60 00 10 00 d0 00 00 01 c4 7c a8 40 08     00:00:16.740  READ FPDMA QUEUED

Error 23 [2] occurred at disk power-on lifetime: 9 hours (0 days + 9 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  04 -- 51 10 45 00 00 00 00 00 00 e0 00

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  ec d2 00 45 00 00 00 00 00 00 00 00 00     00:00:03.690  IDENTIFY DEVICE
  b0 00 d2 00 f1 00 00 00 c2 4f 00 00 00     00:00:03.690  SMART ENABLE/DISABLE 
ATTRIBUTE AUTOSAVE
  ec 03 00 45 00 00 00 00 00 00 00 00 00     00:00:03.690  IDENTIFY DEVICE
  ef 00 03 10 45 00 00 00 00 00 00 00 00     00:00:03.690  SET FEATURES [Set 
transfer mode]
  c6 03 00 0c 10 00 00 00 00 00 00 00 00     00:00:03.690  SET MULTIPLE MODE

Error 22 [1] occurred at disk power-on lifetime: 6 hours (0 days + 6 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  04 -- 51 00 fe 00 00 00 00 00 00 40 08  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  ef 00 05 00 fe 00 00 00 00 00 00 40 08     00:00:17.790  SET FEATURES [Enable 
APM]
  60 00 08 00 48 00 00 09 00 08 80 40 08     00:00:17.750  READ FPDMA QUEUED
  60 00 08 00 40 00 00 01 c4 0a a8 40 08     00:00:17.740  READ FPDMA QUEUED
  60 00 20 00 38 00 00 0c c5 4c 60 40 08     00:00:17.680  READ FPDMA QUEUED
  60 00 20 00 30 00 00 0c c5 4c 40 40 08     00:00:17.680  READ FPDMA QUEUED

Error 21 [0] occurred at disk power-on lifetime: 6 hours (0 days + 6 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  04 -- 51 10 45 00 00 00 00 00 00 e0 00  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  b0 00 d2 00 f1 00 00 00 c2 4f 00 00 00     00:00:04.380  SMART ENABLE/DISABLE 
ATTRIBUTE AUTOSAVE
  ec 03 00 45 00 00 00 00 00 00 00 00 00     00:00:04.380  IDENTIFY DEVICE
  ef 00 03 10 45 00 00 00 00 00 00 00 00     00:00:04.380  SET FEATURES [Set 
transfer mode]
  c6 03 00 0c 10 00 00 00 00 00 00 00 00     00:00:04.380  SET MULTIPLE MODE
  ef 00 03 01 0c 00 00 00 00 00 00 00 00     00:00:04.380  SET FEATURES [Set 
transfer mode]

SMART Extended Self-test Log Version: 1 (2 sectors)
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%        11         -

Selective Self-tests/Logging not supported

SCT Commands not supported

Device Statistics (GP Log 0x04)
Page Offset Size         Value  Description
  1  =====  =                =  == General Statistics (rev 2) ==
  1  0x008  4               11  Lifetime Power-On Resets

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x0001  2            0  Command failed due to ICRC error
0x0002  2            0  R_ERR response for data FIS
0x0003  2            0  R_ERR response for device-to-host data FIS
0x0004  2            0  R_ERR response for host-to-device data FIS
0x0005  2            0  R_ERR response for non-data FIS
0x0006  2            0  R_ERR response for device-to-host non-data FIS
0x0007  2            0  R_ERR response for host-to-device non-data FIS
0x0008  2            0  Device-to-host non-data FIS retries
0x0009  2            0  Transition from drive PhyRdy to drive PhyNRdy
0x000a  2            9  Device-to-host register FISes sent due to a COMRESET
0x000b  2            0  CRC errors within host-to-device FIS
0x000d  2            0  Non-CRC errors within host-to-device FIS
0x000f  2            0  R_ERR response for host-to-device data FIS, CRC
0x0010  2            0  R_ERR response for host-to-device data FIS, non-CRC
0x0012  2            0  R_ERR response for host-to-device non-data FIS, CRC
0x0013  2            0  R_ERR response for host-to-device non-data FIS, non-CRC
------------------------------------------------------------------------------
Monitor Your Dynamic Infrastructure at Any Scale With Datadog!
Get real-time metrics from all of your servers, apps and tools
in one place.
SourceForge users - Click here to start your Free Trial of Datadog now!
http://pubads.g.doubleclick.net/gampad/clk?id=241902991&iu=/4140
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to