-- *"Eis o meu segredo. É muito simples: só se vê bem com o coração. O essencial é invisível para os olhos." * Antoine de Saint-Exupéry
(¯`·._.·[ MaptaN ]·._.·´¯)
=== START OF INFORMATION SECTION === Device Model: HGST HTS545050A7E680 Firmware Version: GR2OA230 User Capacity: 500,107,862,016 bytes [500 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 6 Local Time is: Mon Sep 28 13:49:06 2015 BRT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 45) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 102) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0 2 Throughput_Performance P-S--- 100 100 040 - 0 3 Spin_Up_Time POS--- 222 222 033 - 1 4 Start_Stop_Count -O--C- 100 100 000 - 34 5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0 7 Seek_Error_Rate PO-R-- 100 100 067 - 0 8 Seek_Time_Performance P-S--- 100 100 040 - 0 9 Power_On_Hours -O--C- 086 086 000 - 6354 10 Spin_Retry_Count PO--C- 100 100 060 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 34 191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0 192 Power-Off_Retract_Count -O--CK 100 100 000 - 10 193 Load_Cycle_Count -O--C- 001 001 000 - 1592700 194 Temperature_Celsius -O---- 200 200 000 - 30 (Min/Max 21/38) 196 Reallocated_Event_Count -O--CK 100 100 000 - 0 197 Current_Pending_Sector -O---K 100 100 000 - 0 198 Offline_Uncorrectable ---R-- 100 100 000 - 0 199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0 223 Load_Retry_Count -O-R-- 100 100 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] GP/S Log at address 0x00 has 1 sectors [Log Directory] SMART Log at address 0x01 has 1 sectors [Summary SMART error log] SMART Log at address 0x02 has 1 sectors [Comprehensive SMART error log] GP Log at address 0x03 has 1 sectors [Ext. Comprehensive SMART error log] SMART Log at address 0x06 has 1 sectors [SMART self-test log] GP Log at address 0x07 has 1 sectors [Extended self-test log] SMART Log at address 0x09 has 1 sectors [Selective self-test log] GP Log at address 0x10 has 1 sectors [NCQ Command Error log] GP Log at address 0x11 has 1 sectors [SATA Phy Event Counters] GP/S Log at address 0x80 has 16 sectors [Host vendor specific log] GP/S Log at address 0x81 has 16 sectors [Host vendor specific log] GP/S Log at address 0x82 has 16 sectors [Host vendor specific log] GP/S Log at address 0x83 has 16 sectors [Host vendor specific log] GP/S Log at address 0x84 has 16 sectors [Host vendor specific log] GP/S Log at address 0x85 has 16 sectors [Host vendor specific log] GP/S Log at address 0x86 has 16 sectors [Host vendor specific log] GP/S Log at address 0x87 has 16 sectors [Host vendor specific log] GP/S Log at address 0x88 has 16 sectors [Host vendor specific log] GP/S Log at address 0x89 has 16 sectors [Host vendor specific log] GP/S Log at address 0x8a has 16 sectors [Host vendor specific log] GP/S Log at address 0x8b has 16 sectors [Host vendor specific log] GP/S Log at address 0x8c has 16 sectors [Host vendor specific log] GP/S Log at address 0x8d has 16 sectors [Host vendor specific log] GP/S Log at address 0x8e has 16 sectors [Host vendor specific log] GP/S Log at address 0x8f has 16 sectors [Host vendor specific log] GP/S Log at address 0x90 has 16 sectors [Host vendor specific log] GP/S Log at address 0x91 has 16 sectors [Host vendor specific log] GP/S Log at address 0x92 has 16 sectors [Host vendor specific log] GP/S Log at address 0x93 has 16 sectors [Host vendor specific log] GP/S Log at address 0x94 has 16 sectors [Host vendor specific log] GP/S Log at address 0x95 has 16 sectors [Host vendor specific log] GP/S Log at address 0x96 has 16 sectors [Host vendor specific log] GP/S Log at address 0x97 has 16 sectors [Host vendor specific log] GP/S Log at address 0x98 has 16 sectors [Host vendor specific log] GP/S Log at address 0x99 has 16 sectors [Host vendor specific log] GP/S Log at address 0x9a has 16 sectors [Host vendor specific log] GP/S Log at address 0x9b has 16 sectors [Host vendor specific log] GP/S Log at address 0x9c has 16 sectors [Host vendor specific log] GP/S Log at address 0x9d has 16 sectors [Host vendor specific log] GP/S Log at address 0x9e has 16 sectors [Host vendor specific log] GP/S Log at address 0x9f has 16 sectors [Host vendor specific log] GP/S Log at address 0xe0 has 1 sectors [SCT Command/Status] GP/S Log at address 0xe1 has 1 sectors [SCT Data Transfer] SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 6354 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 256 (0x0100) SCT Support Level: 1 Device State: Active (0) Current Temperature: 30 Celsius Power Cycle Min/Max Temperature: 25/36 Celsius Lifetime Min/Max Temperature: 21/38 Celsius Lifetime Average Temperature: 30 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -40/65 Celsius Temperature History Size (Index): 128 (33) Index Estimated Time Temperature Celsius 34 2015-09-28 11:42 30 *********** ... ..( 7 skipped). .. *********** 42 2015-09-28 11:50 30 *********** 43 2015-09-28 11:51 29 ********** 44 2015-09-28 11:52 29 ********** 45 2015-09-28 11:53 29 ********** 46 2015-09-28 11:54 30 *********** ... ..( 7 skipped). .. *********** 54 2015-09-28 12:02 30 *********** 55 2015-09-28 12:03 29 ********** 56 2015-09-28 12:04 30 *********** ... ..( 5 skipped). .. *********** 62 2015-09-28 12:10 30 *********** 63 2015-09-28 12:11 29 ********** ... ..( 15 skipped). .. ********** 79 2015-09-28 12:27 29 ********** 80 2015-09-28 12:28 30 *********** 81 2015-09-28 12:29 29 ********** ... ..( 5 skipped). .. ********** 87 2015-09-28 12:35 29 ********** 88 2015-09-28 12:36 30 *********** ... ..( 25 skipped). .. *********** 114 2015-09-28 13:02 30 *********** 115 2015-09-28 13:03 31 ************ 116 2015-09-28 13:04 31 ************ 117 2015-09-28 13:05 30 *********** 118 2015-09-28 13:06 31 ************ ... ..( 4 skipped). .. ************ 123 2015-09-28 13:11 31 ************ 124 2015-09-28 13:12 30 *********** ... ..( 18 skipped). .. *********** 15 2015-09-28 13:31 30 *********** 16 2015-09-28 13:32 29 ********** ... ..( 3 skipped). .. ********** 20 2015-09-28 13:36 29 ********** 21 2015-09-28 13:37 30 *********** 22 2015-09-28 13:38 29 ********** ... ..( 4 skipped). .. ********** 27 2015-09-28 13:43 29 ********** 28 2015-09-28 13:44 30 *********** 29 2015-09-28 13:45 29 ********** 30 2015-09-28 13:46 30 *********** 31 2015-09-28 13:47 29 ********** 32 2015-09-28 13:48 30 *********** 33 2015-09-28 13:49 30 *********** SCT Error Recovery Control: Read: Disabled Write: Disabled SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 2 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS
------------------------------------------------------------------------------
_______________________________________________ Smartmontools-database mailing list Smartmontools-database@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/smartmontools-database