Please find attached a submission for the disk CT480BX200SSD1
This device may not support self-tests but I trust this output may still be of
use to the project.
smartctl 6.4 2015-06-04 r4109 [i686-w64-mingw32-vista-sp2] (sf-6.4-1)
Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: CT480BX200SSD1
Firmware Version: MU02.6
User Capacity: 480,103,981,056 bytes [480 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: Solid State Device
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-2 (minor revision not indicated)
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Tue Jan 26 10:38:13 2016 GMTST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x02) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 171) seconds.
Offline data collection
capabilities: (0x71) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0002) Does not save SMART data before
entering power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 2) minutes.
Conveyance self-test routine
recommended polling time: ( 1) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0000 100 100 000 Old_age Offline
- 0
5 Reallocated_Sector_Ct 0x0000 100 100 000 Old_age Offline
- 2
9 Power_On_Hours 0x0000 100 100 000 Old_age Offline
- 19
12 Power_Cycle_Count 0x0000 100 100 000 Old_age Offline
- 10
160 Unknown_Attribute 0x0000 100 100 000 Old_age Offline
- 0
161 Unknown_Attribute 0x0000 100 100 000 Old_age Offline
- 52
163 Unknown_Attribute 0x0000 100 100 000 Old_age Offline
- 630
148 Unknown_Attribute 0x0000 100 100 000 Old_age Offline
- 14664
149 Unknown_Attribute 0x0000 100 100 000 Old_age Offline
- 274
150 Unknown_Attribute 0x0000 100 100 000 Old_age Offline
- 136
151 Unknown_Attribute 0x0000 100 100 000 Old_age Offline
- 225
164 Unknown_Attribute 0x0000 100 100 000 Old_age Offline
- 4990
165 Unknown_Attribute 0x0000 100 100 000 Old_age Offline
- 4
166 Unknown_Attribute 0x0000 100 100 000 Old_age Offline
- 3
167 Unknown_Attribute 0x0000 100 100 000 Old_age Offline
- 4
169 Unknown_Attribute 0x0000 100 100 001 Old_age Offline
- 100
181 Program_Fail_Cnt_Total 0x0000 100 100 000 Old_age Offline
- 0
182 Erase_Fail_Count_Total 0x0000 100 100 000 Old_age Offline
- 0
192 Power-Off_Retract_Count 0x0000 100 100 000 Old_age Offline
- 1
194 Temperature_Celsius 0x0000 100 100 070 Old_age Offline
- 24 (30 29 30 31 0)
199 UDMA_CRC_Error_Count 0x0000 100 100 000 Old_age Offline
- 0
232 Available_Reservd_Space 0x0000 100 100 000 Old_age Offline
- 100
241 Total_LBAs_Written 0x0000 100 100 000 Old_age Offline
- 57249
242 Total_LBAs_Read 0x0000 100 100 000 Old_age Offline
- 14314
245 Unknown_Attribute 0x0000 100 100 000 Old_age Offline
- 58944
246 Unknown_Attribute 0x0000 100 100 000 Old_age Offline
- 58656
247 Unknown_Attribute 0x0000 100 100 000 Old_age Offline
- 0
SMART Error Log Version: 1
ATA Error Count: 0
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error -4 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was in an unknown
state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
00 ec 00 00 00 00 00 Device Fault
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 00 00 00 00 00 00 00:00:00.000 READ DMA
Warning! SMART Self-Test Log Structure error: invalid SMART checksum.
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Extended offline Completed without error 00% 19 -
# 2 Offline Completed without error 00% 18 -
# 3 Conveyance offline Completed without error 00% 0 -
# 4 Short offline Completed without error 00% 0 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
7 0 65535 Read_scanning was completed without error
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
Site24x7 APM Insight: Get Deep Visibility into Application Performance
APM + Mobile APM + RUM: Monitor 3 App instances at just $35/Month
Monitor end-to-end web transactions and take corrective actions now
Troubleshoot faster and improve end-user experience. Signup Now!
http://pubads.g.doubleclick.net/gampad/clk?id=267308311&iu=/4140
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database