smartctl 6.3 2014-07-26 r3976 [i686-w64-mingw32-win7(64)-sp1] (sf-6.3-1)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     HGST HDN728080ALE604
Serial Number:    VLKSZJEY
LU WWN Device Id: 5 000cca 260f52da7
Firmware Version: A4GNW91X
User Capacity:    8 001 563 222 016 bytes [8,00 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    7200 rpm
Form Factor:      3.5 inches
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-2, ATA8-ACS T13/1699-D revision 4
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is:    Thu Jun 15 02:37:25 2017 FLEDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM level is:     164 (intermediate level without standby)
Rd look-ahead is: Enabled
Write cache is:   Enabled
ATA Security is:  Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x84) Offline data collection activity
                                        was suspended by an interrupting 
command from host.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                (  101) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (1301) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   100   100   016    Pre-fail  Always       
-       0
  2 Throughput_Performance  0x0005   100   100   054    Pre-fail  Offline      
-       0
  3 Spin_Up_Time            0x0007   100   100   024    Pre-fail  Always       
-       0
  4 Start_Stop_Count        0x0012   100   100   000    Old_age   Always       
-       3
  5 Reallocated_Sector_Ct   0x0033   100   100   005    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x000b   100   100   067    Pre-fail  Always       
-       0
  8 Seek_Time_Performance   0x0005   100   100   020    Pre-fail  Offline      
-       0
  9 Power_On_Hours          0x0012   100   100   000    Old_age   Always       
-       0
 10 Spin_Retry_Count        0x0013   100   100   060    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       2
 22 Unknown_Attribute       0x0023   100   100   025    Pre-fail  Always       
-       100
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       
-       3
193 Load_Cycle_Count        0x0012   100   100   000    Old_age   Always       
-       3
194 Temperature_Celsius     0x0002   222   222   000    Old_age   Always       
-       27 (Min/Max 25/31)
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       
-       0
197 Current_Pending_Sector  0x0022   100   100   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0008   100   100   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x000a   200   200   000    Old_age   Always       
-       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%         0         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
Check out the vibrant tech community on one of the world's most
engaging tech sites, Slashdot.org! http://sdm.link/slashdot
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to