Hi,


NOTICE: System detected 256 cpus, but only 1 cpu(s) were enabled during boot

NOTICE: unsupported 64-bit prefetch memory on pci-pci bridge [0/2/2]

WARNING: KCS error: ff



https://blog.plitc.eu/2016/smartos-on-hpe-proliant-dl380-gen9-server/



need BIOS setting changes:



HP -> System Configuration (RBSU) -> UEFI auf Legacy BIOS Mode stellen

HP -> Processor x2APIC Support disabled

HP -> Fibre Channel/FCoE Scan Policy auf Scan All Targets

HP -> Embedded NIC disabled / fixed: 
https://github.com/illumos/illumos-gate/commit/67150631bf9ca4bc6c5535394eb0968ad069b6ab

HP -> ASR Status disabled

HP -> Smart Array kein HBA Mode sondern Laufwerke zu logischen Gruppen mit 
einzelnem Raid 0 erstellen

HP -> Virtualization -> SR-IOV disabled



WARNING: KCS error: ff / SmartOS can't find IPMI Connection, ignore this 
because the HP Machine has HP iLO


Mit freundlichen Grüßen


DANIEL PLOMINSKI
Leiter - IT / Head of IT

Telefon 09265 808-151  |  Mobil 0151 58026316  |  
[email protected]<mailto:[email protected]>
PGP Key: http://pgp.ass.de/2B4EB20A.key


[cid:C17DB6FB-5F79-4BCC-AAB4-CAB59266BC29@localdomain]

ASS-Einrichtungssysteme GmbH
ASS-Adam-Stegner-Straße 19  |  D-96342 Stockheim

Geschäftsführer: Matthias Stegner, Michael Stegner, Stefan Weiß
Amtsgericht Coburg HRB 3395  |  Ust-ID: DE218715721

[cid:E40AEC87-91EE-472A-901A-ECAD3F5801FB@localdomain]


-----Ursprüngliche Nachricht-----
Von: Paul Sture [mailto:[email protected]]
Gesendet: Freitag, 18. August 2017 13:13
An: [email protected]
Betreff: Re: [smartos-discuss] vmadm create times out (but zone eventually 
starts) on DL360g6



On 18 Aug 2017, at 3:31, Rob Seastrom wrote:



> OK, must be the disk subsystem right?  Picked up some HP H220s

> (SAS2308 aka 9207s) and reflashed to IT mode.  System boots but throws

> an odd error in the middle of booting:  "warning: KCS error: ff" -

> Google tells me little except that maybe bmc is weird about the card.

> Disabled the built-in SmartArray just in case.
 
 
 I see the "WARNING KCS error: ff" on a HP Gen8.  On the basis of the research 
I did when this system was new I simply stopped worrying about it.
 
 Disabling the HP RAID was the first thing I did when this box was new.
 
 Do you have the option of trying a third party disk controller?
 



-------------------------------------------
smartos-discuss
Archives: https://www.listbox.com/member/archive/184463/=now
RSS Feed: https://www.listbox.com/member/archive/rss/184463/25769125-55cfbc00
Modify Your Subscription: 
https://www.listbox.com/member/?member_id=25769125&id_secret=25769125-7688e9fb
Powered by Listbox: http://www.listbox.com

Reply via email to