Hi Calvin, Today Calvin Park wrote:
> Hello SmokePing Users ~ > > Below info. is RRD schema. > > name ( ex : uptime, loss ... ) > type ( ex : GAUGE, COUNTER... ) > min. heart beat ( ex : 300, 600 ) > min > max > last_DS > value > unknown_sec <--- this > > Could you explain to me what's used for 'unknow_sec' field ? unknown seconds are the number of seconds within an interval that have no valid data. If more than 50% of a base interval (step) is filled with unknown data, then the complete periode is considered to be of unknownn value. cheers tobi > > Thank you . Have a good weekends ~ > > _______________________________________________ > smokeping-users mailing list > [email protected] > https://lists.oetiker.ch/cgi-bin/listinfo/smokeping-users > > -- Tobi Oetiker, OETIKER+PARTNER AG, Aarweg 15 CH-4600 Olten, Switzerland http://it.oetiker.ch [email protected] ++41 62 775 9902 / sb: -9900 _______________________________________________ smokeping-users mailing list [email protected] https://lists.oetiker.ch/cgi-bin/listinfo/smokeping-users