Hi Thanasis,

I update source to v3.3.3.

Now, When I use:

--------------
1) Nokia blutooth modem I am getting O/P :

Version: 3.3.3
0 [Thread-1] WARN org.smslib  - GTW: modem.com5: Retrying the
detection of CNMI, modem busy?
3027 [Thread-1] WARN org.smslib  - GTW: modem.com5: Retrying the
detection of CNMI, modem busy?
6055 [Thread-1] WARN org.smslib  - GTW: modem.com5: Retrying the
detection of CNMI, modem busy?
9067 [Thread-1] WARN org.smslib  - GTW: modem.com5: CNMI detection
failed, proceeding with defaults.
9067 [Thread-1] WARN org.smslib  - GTW: modem.com5: Callback
indications were *not* set succesfully!
>>> Gateway Status change for modem.com5, OLD: STOPPED -> NEW: RUNNING

Modem Information:
  Manufacturer: Nokia

  Model: Nokia 6300
  Serial No: 356415027151075
  SIM IMSI: ** MASKED **
  Signal Level: 58%
  Battery Level: 81%

Now Sleeping - Hit <enter> to terminate.
-------------------------

2) HUAWEI GMS MODEM, I am getting O/P:

Version: 3.3.3
>>> Gateway Status change for modem.com6, OLD: STOPPED -> NEW: RUNNING

Modem Information:
  Manufacturer: huawei
  Model: EG162G
  Serial No: 353474020522298
  SIM IMSI: ** MASKED **
  Signal Level: 54%
  Battery Level: 0%

0 [main] ERROR org.smslib  - GTW: modem.com6: Wrong type of PDU
detected: org.ajwcc.pduUtils.gsm3040.SmsSubmitPdu
0 [main] ERROR org.smslib  - GTW: modem.com6: ERROR PDU:
079119892270080011640C911949124999550000A72EC86463356C1EAF3A50AC11A43656C3E6F1AA8B3556C3E691D98B35844AA4B2815C0A994625B3216A00
Now Sleeping - Hit <enter> to terminate.
2434 [SMSLib-CNMIEmulator : modem.com6] ERROR org.smslib  - GTW:
modem.com6: Wrong type of PDU detected:
org.ajwcc.pduUtils.gsm3040.SmsSubmitPdu
2434 [SMSLib-CNMIEmulator : modem.com6] ERROR org.smslib  - GTW:
modem.com6: ERROR PDU:
079119892270080011640C911949124999550000A72EC86463356C1EAF3A50AC11A43656C3E6F1AA8B3556C

-----------------------------------------


I remember that i successfully run the ReadMessage.java. And i was
been able to get the o/p successfully.

Now, what happen. i don't know.
Help.

Thank you.



On Mar 17, 1:21 am, Thanasis <[email protected]> wrote:
> Please upgrade to the latest v3.3.3 version and try once more.
>
> On Mar 16, 7:40 pm, Rahul Boss <[email protected]> wrote:
>
>
>
> > Hi,
>
> > I am going through the DOC of GSM Modem.
>
> > Mean while i used My NOKIA 6300 Blutooth Modem.
> > and write
> > setStorageLocations("MTSMME"); on the last line of constructor of
> > ATHandler.java
>
> > its giving me o/p like this:
> > --------------------------------------------------
> > Version: 3.0.1
> > 1 [main] WARN org.smslib  - Callback indications were *not* set
> > succesfully!
>
> > Modem Information:
> >   Manufacturer: Nokia
> >   Model: Nokia 6300
> >   Serial No: 356415027151075
> >   SIM IMSI: * MASKED *
> >   Signal Level: 54%
> >   Battery Level: 94%
>
> >  Sim Pin is : 0000
> > Now Sleeping - Hit <enter> to terminate.
> > -------------------------------------------------
>
> > Whats the problem here?
>
> > On Mar 16, 1:07 am, Thanasis <[email protected]> wrote:
>
> > > The storage ids are two-letter words. For example, the "SM" refers to
> > > the SIM memory.
>
> > > If you are brave enough, you can try with trial-and-error. To do this:
>
> > > 1) Edit ATHandler.java and add as the last constructor line the line:
> > > setStorageLocations("MTSMME");
>
> > > 2) Try to see if you can now read the messages stored in your modem.
>
> > > 3) If you do, the ID you are looking for must be one of "MT" or "ME" -
> > > try the combinations. If not, then you should really look at your
> > > modem's documentation - the ID could be any two-letter word...
>
> > > On Mar 15, 9:59 pm, Rahul Boss <[email protected]> wrote:
>
> > > > I gone through the Class InboundMessage and it has setMemIndex() and
> > > > setMemLocation() methods.
> > > > will these methods help me. but How & where can i call these methods
> > > > or where can i use this methods inside ReadMessage class?
>
> > > > Lets hope for the best. i'll search any doc.
>
> > > > On Mar 15, 11:26 pm, Thanasis <[email protected]> wrote:
>
> > > > > It seems that the modem does not report back the storage identifier
> > > > > which refers to its memory.
> > > > > There is not much I can do, unless you have some documentation which
> > > > > clearly states which is the identifier of the build-in modem memory.
>
> > > > > On Mar 15, 2:45 pm, Rahul Boss <[email protected]> wrote:
>
> > > > > > Hi,
>
> > > > > > I have IDEA NETSETTER GSM MODEM (HUAWEI) MODEL-EG162G.
>
> > > > > > My GSM Device has 2 memory locations
>
> > > > > > 1) GMS Modem memory
> > > > > > 2) SIM Memory
>
> > > > > > When i receive any sms it by default stores in to GSM Modem Memeory.
>
> > > > > > Ultimatly my SIM Memory always remains empty.
>
> > > > > > the big trajedy is that, ReadMessage class when it runs, it is
> > > > > > searching for the SMS which are stored in SIM Memeory. And
> > > > > > unfortunatly there is no SMS in SIM Memeory.
>
> > > > > > I want to tell ReadMessage class to search messages from GMS Modem
> > > > > > Memory to read it. How can i do it?
>
> > > > > > Other wise, i have to manually put the SMS in SIM card memeory
> > > > > > manually. Which is not possible for me.
>
> > > > > > How can i suggest my program to read message from my Local GSM Modem
> > > > > > Memory and not from the SIM Memeory?
>
> > > > > > Please help me...- Hide quoted text -
>
> > > > > - Show quoted text -- Hide quoted text -
>
> > > - Show quoted text -- Hide quoted text -
>
> - Show quoted text -
--~--~---------~--~----~------------~-------~--~----~
You received this message because you are subscribed to the Google Groups 
"SMSLib User Group" group.
To post to this group, send email to [email protected]
To unsubscribe from this group, send email to 
[email protected]
For more options, visit this group at 
http://groups.google.com/group/SMSLib?hl=en
-~----------~----~----~----~------~----~------~--~---

Reply via email to