Hi, As posted here already, the problem is the NE (engine boots must not be reset to 0).
Best regards, Frank On 08.02.2011 09:58, Jigar Shah wrote: > Hi, > > I am facing below mentioned problem. > > > I have attached ems_blue.cap file also. > > According to the > ems_blue.cap below is what happening: > 1. NEs (for e.g IPs: > 188.116.222.30, 188.116.247.62 and 109.63.12.120) > sending > snmpTrap to EMS with > engineBoots and engineTime as 0 (Ideally this should > occur > only after rebootstrapping > the NE or restarting CLAgent on the NE) > 2. EMS is sending > notInTimeWindow REPORT to NE with proper engineBoots > and > engineTime > (Expected). > 3. NE is updating and resending snmpTrap with proper engineBoots > and engineTime > (Expected). > 4. EMS is still sending notInTimeWindow REPORT to NE (Looking > weird) > 5. Step 3 and 4 repeated 3 > to 5 times > And because of this System hangs and not sending heartbeats. > > > We > don’t know what is the reason for sending wrong notInTimeWindow report to NE. > > Can you please help me out. > > Thanks& Regards,Jigar Shah > > _______________________________________________ > SNMP4J mailing list > [email protected] > http://lists.agentpp.org/mailman/listinfo/snmp4j -- AGENT++ http://www.agentpp.com http://www.snmp4j.com http://www.mibexplorer.com http://www.mibdesigner.com _______________________________________________ SNMP4J mailing list [email protected] http://lists.agentpp.org/mailman/listinfo/snmp4j