What you are refering to is an internal function of specific RX's that
when sensing a voltage level that is near the operating threshold, will
move the channel normally associated with flaps (or throttle) to it's
opposite position (deployed, or idle).
This function is separate from the other failsafe functions of most
RX's.

[EMAIL PROTECTED] wrote:
> 
> ...PCM (and I think IPD) are programmed to go into fail safe when the voltage
> level drops below 4.8 or 4.7 volts. PCM rx's emit a low battery warning which
> if ignored, will deploy the fail safe mode.
RCSE-List facilities provided by Model Airplane News.  Send "subscribe" and 
"unsubscribe" requests to [EMAIL PROTECTED]