After playing around a bit I see more of a pattern, but am no
closer to an acceptable solution.

> There is then a brief delay and then, seemingly at random, one of
>   Pri Mas  SILICONSYSTEMS INC 2GB          LBA Xlt 1016-64-63  2049 Mbyte
> or
>   Pri Sla  CHS --   Mbyte
> or nothing.

Things aren't quite random.  Detection of the CF works better
with the case open, which is odd because the thing is not
generating much heat and I can't see how else the open case
could make a difference.  On a cold reboot I am most likely to
get "Pri Sla  CHS --   Mbyte".  ^P reboot on the serial console
often gives the desired "Pri Mas  SILICONSYSTEMS INC 2GB
LBA Xlt 1016-64-63  2049 Mbyte".  Reboot within the OS usually
gives nothing.  Once on site the thing needs to reboot cleanly
without a serial console and someone standing by to hit ^P, of
course.

It's pretty clear that there's a timing issue somewhere in
the BIOS and that the time spent checking the memory on a cold
reboot is playing a role.  Any ideas?

-- 