Dear list, personally I prefer to add "console=ttyS0,19200 -- console=ttyS0,19200" to the installer and kernel parameters. This leads to a working serial console right after installation.
Best regards, Martin On 19/01/15 20:54, Johannes Graumann wrote: > Isolinux. The tab thing is tricky, as I do not see anything decypherable > ... will have another look. > > Joh > > Conrad Kostecki wrote: > >>> append vga=788 initrd=/install.386/initrd.gz -- quiet >> >>> Now I have to find out how to mount that darn usb-stick dd'ed image >>> read/write to edit the txt.cfg ... >> >> Is there GRUB or ISOLINUX being used? With TAB, you can edit this comand >> line during startup.. >> >> Removing vga=788 should work and maybe console=ttyS0,XXXXXXn8 would be >> useful, where XXXXXX is your baud rate. >> >> Conrad >
smime.p7s
Description: S/MIME Cryptographic Signature
_______________________________________________ Soekris-tech mailing list [email protected] http://lists.soekris.com/mailman/listinfo/soekris-tech
