--- In [email protected], "ad9850" <[EMAIL PROTECTED]> wrote:
>
> Hi,
> 
> I got my Lite+XTALL v.8.3 kit a few days ago and finished assembling.
> Here are the measured MDS data for all bands. I programmed the PIC
> with Tom's XTALL v2.4 data. The Si570 is the LVDS version.
> 
> center frequency    MDS / dBm
> 
>    28.046 MHz         -125
>    24.936 MHz         -126
>    21.046 MHz         -126
>    18.114 MHz         -127
>    14.046 MHz         -127
>    10.146 MHz         -128
>     7.046 MHz         -129
>     3.546 MHz         -128
>     1.846 MHz         -128
> 
> Tony, thanks for this great kit!
> 
> 73 Bodo, DJ9CS
>

Hi Bodo, Will you tell us the detailed test setup you used to
determine your MDS figures? Test eqpt. type etc.? Or perhaps steer us
to a page where standardized MDS methodologies used for these SDRs are
described?

Tnx - David


Reply via email to