hello Dan,

have you tried resetting the OBP variables to their defaults? you can try
while at the ok prompt to do:
set-defaults
reset-all
here is a link to the LOM users guide:
http://www.filibeto.org/products-n-solutions/hardware/docs/pdf/806-2038-10.pdf

hope this helps.

Stoyan

----- Original Message ----- 
From: "Dan O'Callaghan" <[EMAIL PROTECTED]>
To: "Solaris-Users (E-mail)" <[EMAIL PROTECTED]>
Sent: Monday, January 26, 2004 6:43 PM
Subject: [Solaris-Users] Console acces on Netra T1


> Hi
>
> I've been given 2 Netra T1s to build.
>
> I'm having problems with the output of the console connection (LOM-A
> port).
> I can access the LOM without any problems with a standard "tip -9600
> /dev/ttya" on an E250.
> Once i'm on the LOM all output is correct to the tip session is correct.
>
> As soon as i enter the "console" from withinn the LOM and type boot, the
> screen output goes all over the place, as if the terminal session was the
> wrong type.
>
> Is there any specific terminal type or any LOM setting to correct this?
> I'm using a "ddterm" on the E250 for the connection.
>
> Thanks in advance,
> dan
>
> ###########################################
>
> This message has been scanned by F-Secure Anti-Virus for Microsoft
> Exchange.
> For more information, connect to http://www.F-Secure.com/
>
> _______________________________________________
> Solaris-Users mailing list
> [EMAIL PROTECTED]
> http://www.filibeto.org/mailman/listinfo/solaris-users
>
>


_______________________________________________
Solaris-Users mailing list
[EMAIL PROTECTED]
http://www.filibeto.org/mailman/listinfo/solaris-users

Reply via email to