We are having issues with the topology discovery of servers with multiple NICs. 
The servers are configrued with NIC teaming and transmit load balancing, so the 
virtual MAC floats between the active transmit NIC. 

During autodiscovery, Spectrum only connects the active trasmit NIC to a switch 
model. CA support said this is expected as they only see one MAC address during 
the discovery. However, both physical MAC addresses are available using the 
hardware MIB rather than the Intel Teaming MIB. 

When I questioned support if other enterprise customers had this issue, he said 
he was unaware of otehr cusomers using redundant NICs, but they could submit an 
enhancement request.... 

Has anyone else had any luck with discovery of servers with Teamed NICs? 

---
To unsubscribe from spectrum, send email to [email protected] with the body: 
unsubscribe spectrum [email protected]