On Nov 2, 2011, at 7:45 AM, <[email protected]> <[email protected]> wrote:
> Hi everyone, > > my customer has got Spectrum 9.2.1 installed on 3 Windows 2003 servers > (SpectroServer, OneClick and BOXI). We have made a new Spectrum installation > and during the process we used databases > (DDM and SSDb) from older version 8.1. Everything was ok. Now we have > problems with creating watches. > > There are old watches that are created&inherited from the version 8.1 and > they are ok when I activate them. If I copy them or create new watches and > try to activate them I keep getting the message 'There is a syntax error in > the watch expression'. No matter which watch I try to create this message > pops out. I've tried to create watches on devices, interfaces, tried to use > inherited attributes, created attributes, with no success. > > I've searched the knowledge base and forum but there's nothing helpful. Do > you maybe have an idea what's the reason for this happening? I have had similar problems with copying and editing watches in 9.2.1 on Linux, and I have found a few things that help. When copying, I have had more success copying the text of the watch from the information view of the watch I intend to copy rather than using the copy button. When editing, I have found that making sure there are spaces between parenthesis and anything else - like REAL ( ATTRIBUTE ) rather than REAL(ATTRIBUTE). Mathias Wegner Sr Network Engineer University of Pennsylvania --- To unsubscribe from spectrum, send email to [email protected] with the body: unsubscribe spectrum [email protected]