On 23.01.2012 09:26, Hofmann, Berthold wrote:

Hi,

> We have the problem, on enterasys devices must a engineid 
> defined, but what is the value in spectrum, which must 
> defined on the enterasys switches.
> 
The engine_ID must be unique in your network, there are no other limitation.
Spectrum will learn it from the device.

RfC 2571

3.1.1.1.  snmpEngineID

   Within an administrative domain, an snmpEngineID is the unique and
   unambiguous identifier of an SNMP engine. Since there is a one-to-one
   association between SNMP engines and SNMP entities, it also uniquely
   and unambiguously identifies the SNMP entity within that
   administrative domain.  Note that it is possible for SNMP entities in
   different administrative domains to have the same value for
   snmpEngineID.  Federation of administrative domains may necessitate
   assignment of new values.

H.
-- 
amasol Kundentag, 29. März 2012, Campus Neue Balan

  Hilmar Preuße                   amasol AG
  Senior Consultant               Campus Neue Balan
  Tel   +49 89 1894743-18         Claudius-Keller-Straße 3b
  Fax   +49 89 1894743-99         D-81669 München
  eMail [email protected]         http://www.amasol.de/

amasol Aktiengesellschaft für Informations- und Kommunikationstechnologie
Aufsichtsrat: Prof. Dr. Stephan Kaiser (Vorsitzender)
Vorstand: Wolfgang Bachmann, Stefan Deml, Thomas Dirsch, Frank Jahn
          Johann Maurer
Amtsgericht München HRB 128327, Sitz der Gesellschaft München

---
To unsubscribe from spectrum, send email to [email protected] with the body: 
unsubscribe spectrum [email protected]

Reply via email to