Hello all. I'm facing a potential issue. "Event Rate rules" doesn't work i expected. and more particularly the "Sliding Window". In the documentation (CA Spectrum Event configuation User Guide, page 63) i read : "When a sliding time window is used for a rule, if the rule generates a rule output event, all active time windows are terminated, and a new time window automatically begins." Except that it does not work. When the rule output event is generated (once), no more instances are possible before the time window is elapsed.
The easy way to face this problem : Make a rule that watches in example for 5 instances of a given event in 3 minutes time window, and generate 10, 11 or much more events in this time window, and you got one alarm and only one. ??? have you experienced this? Is this a bug ? Regards [Signature de mail-logo MMA] Pascal BRUN Intervenant CA Spectrum Site Californie 73 - Bureau C236 160 Rue Henri Champion - 72000 Le Mans Tél. : 02 43 41 79 10 --- To unsubscribe from spectrum, send email to lists...@unc.edu with the body: unsubscribe spectrum arch...@mail-archive.com