ons 2006-12-27 klockan 16:20 -0300 skrev Gonzalo Arana: > I've come across select_loop counter wrap (currently it is an 'int' variable).
which for most things isn't a problem.. counters do wrap. It's a problem when gauges wraps, but not really a problem when counters wrap unless something reads the counter as an absolute value since startup and not a counter.. > Shouldn't counters be at least unsigned? Most isn't.. > Does anyone disagree with having 64 bit unsigned counters? The > drawbacks I see are: > 1) 3rd party utility that parse cache manager information must support > 64 bit unsigned values > 2) and that snmp mibs should be changed accordingly. What would the real use benefits be of changing the MIB? I'm fine with making the counter a long internally if that helps, but I just don't see the point of making it a 64-bit SNMP counter. Regards Henrik
signature.asc