Hi Peter

Great work on this! We'd like to help you test.

The test I have in mind, which we could create using SIPp, would be to
register multiple contacts with the same instance-id (i.e. "sip.instance"
param) but different reg-id params. Then send an INVITE to that AoR and
make sure the forking is only per instance-id and not per reg-id. This
could be repeated in multiple permutations of instance-ids and reg-ids.

This would be a test of save() and lookup() more than anything else. Is
that what you had in mind?

Richard


On 3 January 2013 14:13, Peter Dunkley <[email protected]>wrote:

> I hope to get the outbound edge proxy and flow timer stuff into master by
> Monday, but it could really do with some additional testing especially in
> conjunction with the reg-id stuff in registrar/usrloc (which I have no idea
> how to use).
>
> Peter
>
>
_______________________________________________
sr-dev mailing list
[email protected]
http://lists.sip-router.org/cgi-bin/mailman/listinfo/sr-dev

Reply via email to