Hello all.
I have created a WebRTC to SIP gateway. I implemented it using the outbound
module. If I restart Kamailio during a call, subsequent messages fail to be
routed.
{1 322 BYE [email protected]} INFO: outbound [outbound_mod.c:261]:
decode_flow_token(): flow-token failed validation
{1 322 BYE [email protected]} INFO: rr [loose.c:519]:
process_outbound(): failed to decode flow token
{1 322 BYE [email protected]} INFO: rr [loose.c:794]: after_loose():
failed to process outbound flow-token
Is it possible to make the flow token survive a restart?