Hi We have two registrars.
Today I observed a CPE doing this: CPE REGISTER (no auth) => Registrar 1 => 407 Challenge NONCE A CPE REGISTER (auth to NONCE A => Registrar 2 => 407 Challenge NONCE B CPE REGISTER (auth to NONCE B => Registrar 1 => 407 Challenge NONCE A and so on. Time on both registrars is in sync (I tought NONCE was based on time) Is there a way to sync the NONCE so that both would accept authentication based on the same NONCE? Mit freundlichen Grüssen -Benoît Panizzon- -- I m p r o W a r e A G - Leiter Commerce Kunden ______________________________________________________ Zurlindenstrasse 29 Tel +41 61 826 93 00 CH-4133 Pratteln Fax +41 61 826 93 01 Schweiz Web http://www.imp.ch ______________________________________________________ __________________________________________________________ Kamailio - Users Mailing List - Non Commercial Discussions To unsubscribe send an email to [email protected] Important: keep the mailing list in the recipients, do not reply only to the sender! Edit mailing list options or unsubscribe: