satyaprakash ch via sr-users writes:

> We are receiving 2 to 3 contact headers in the 200 OK response of the
> registration request. It appears that the `user_location` is updating
> multiple contact headers for the same extension due to network
> disconnections. Please suggest a solution to avoid duplicates in the
> `user_location` module, or how to ensure that only the latest single
> contact header is included in the 200 OK response.
> 
> Your suggestion would be appreciated.

Use proper SIP UAs that support instance id.  See
https://www.rfc-editor.org/rfc/rfc5626.

-- Juha