satyaprakash ch via sr-users writes: > We are receiving 2 to 3 contact headers in the 200 OK response of the > registration request. It appears that the `user_location` is updating > multiple contact headers for the same extension due to network > disconnections. Please suggest a solution to avoid duplicates in the > `user_location` module, or how to ensure that only the latest single > contact header is included in the 200 OK response. > > Your suggestion would be appreciated.
Use proper SIP UAs that support instance id. See https://www.rfc-editor.org/rfc/rfc5626. -- Juha __________________________________________________________ Kamailio - Users Mailing List - Non Commercial Discussions To unsubscribe send an email to sr-users-le...@lists.kamailio.org Important: keep the mailing list in the recipients, do not reply only to the sender! Edit mailing list options or unsubscribe: