From: Erik J. Staab <[email protected]>

commit 0873a5ae747847ee55a63db409dff3476e45bcd9 upstream.

On the HT-Omega Claro halo card, the ADC data must be captured from the
second I2S input.  Using the default first input, which isn't connected
to anything, would result in silence.

Signed-off-by: Erik J. Staab <[email protected]>
Signed-off-by: Clemens Ladisch <[email protected]>
Signed-off-by: Takashi Iwai <[email protected]>
Signed-off-by: Paul Gortmaker <[email protected]>
---
 sound/pci/oxygen/oxygen.c |    4 ++++
 1 files changed, 4 insertions(+), 0 deletions(-)

diff --git a/sound/pci/oxygen/oxygen.c b/sound/pci/oxygen/oxygen.c
index 289cb4d..6c0a11a 100644
--- a/sound/pci/oxygen/oxygen.c
+++ b/sound/pci/oxygen/oxygen.c
@@ -543,6 +543,10 @@ static int __devinit get_oxygen_model(struct oxygen *chip,
                chip->model.suspend = claro_suspend;
                chip->model.resume = claro_resume;
                chip->model.set_adc_params = set_ak5385_params;
+               chip->model.device_config = PLAYBACK_0_TO_I2S |
+                                           PLAYBACK_1_TO_SPDIF |
+                                           CAPTURE_0_FROM_I2S_2 |
+                                           CAPTURE_1_FROM_SPDIF;
                break;
        }
        if (id->driver_data == MODEL_MERIDIAN ||
-- 
1.7.3.3