commit: 09e87e5c4f9af656af2a8a3afc03487c5d9287c3 From: Nikolaus Schulz <[email protected]> Date: Wed, 8 Feb 2012 18:56:08 +0100 Subject: hwmon: (f75375s) Fix automatic pwm mode setting for F75373 & F75375
In order to enable temperature mode aka automatic mode for the F75373 and F75375 chips, the two FANx_MODE bits in the fan configuration register need be set to 01, not 10. Signed-off-by: Nikolaus Schulz <[email protected]> Cc: [email protected] # 2.6.32+ Signed-off-by: Guenter Roeck <[email protected]> --- drivers/hwmon/f75375s.c | 2 +- 1 files changed, 1 insertions(+), 1 deletions(-) diff --git a/drivers/hwmon/f75375s.c b/drivers/hwmon/f75375s.c index eedf574..c81ad45 100644 --- a/drivers/hwmon/f75375s.c +++ b/drivers/hwmon/f75375s.c @@ -369,7 +369,7 @@ static int set_pwm_enable_direct(struct i2c_client *client, int nr, int val) fanmode |= (3 << FAN_CTRL_MODE(nr)); break; case 2: /* AUTOMATIC*/ - fanmode |= (2 << FAN_CTRL_MODE(nr)); + fanmode |= (1 << FAN_CTRL_MODE(nr)); break; case 3: /* fan speed */ break; -- 1.7.3.4 -- To unsubscribe from this list: send the line "unsubscribe stable" in the body of a message to [email protected] More majordomo info at http://vger.kernel.org/majordomo-info.html