On Fri, May 25, 2012 at 11:12:38AM +0200, Peter Korsgaard wrote:
> Data valid gets cleared by reading the ISR (status register) and NOT from
> reading ODATA (data register). A new data word can become available between
> checking ISR and reading ODATA, causing us to reuse the same data word next
> time atmel_trng_read() gets called, if that happens before the following
> data word is ready.

Patch applied crypto.  Thanks!
-- 
Email: Herbert Xu <[email protected]>
Home Page: http://gondor.apana.org.au/~herbert/
PGP Key: http://gondor.apana.org.au/~herbert/pubkey.txt
--
To unsubscribe from this list: send the line "unsubscribe stable" in
the body of a message to [email protected]
More majordomo info at  http://vger.kernel.org/majordomo-info.html