Greetings Farid.
I checked the provided test case again on my local installation, and
discovered that it does not replicate the issue.
After further digging, I have found that the problem seems to have been
the use of the %G or %H variable in a for loop prior to invoking devenv.
This was worked around by using the SETLOCAL/ENDLOCAL directives.
As batch scripts alter their environment unless the SETLOCAL command is
used, I had been reducing my test case in an environment where these
variables were undesirably set.
--Andrew Black
Farid Zaripov wrote:
-----Original Message-----
From: Andrew Black [mailto:[EMAIL PROTECTED]
Sent: Monday, October 30, 2006 6:06 PM
To: [email protected]
Subject: Re: Windows infrastructure bug
It was attached as test~bat.txt (with the original name being
test.bat)
I assume that a mail server (probably the apache list
server) mangled the file name as a safety measure.
The contents of the file are very simple though:
call generate.bat /CONFIG:msvc-8.0 /BUILDDIR:%~dp0\build
/LOCALES:no
/LOCALETESTS:no
call build\build_msvc-8.0.bat 15d
I can't reproduce the bug on my workstation.
BTW I don't see the output from the compiler within config.log file
(only linker output is present).
I discovered that cl.exe (MSVC 8.0) redirect output to the named pipe
instead of console
If VS_UNICODE_OUTPUT environment variable is set:
http://blogs.msdn.com/freik/archive/2006/04/05/569025.aspx
I've updated configure.wsf script:
http://svn.apache.org/viewvc?view=rev&rev=469534
Please, try this and sent to me the new config.log file if this
problem still present.
Farid.