What on *earth* does that error message mean? I'm trying to get a HSG80 (DEC 
FC-attached SCSI RAID) connected to a Solaris 10 server via 'ifp', but all I 
get is this error. The RAID unit is attached via a FC hub (together with a 
bunch of A5000 arrays that work just fine) and the HSG80 sees the Sun server 
just fine and claims everything is just fine...

However the Sun server refuses to handle it... (It used to work fine when it 
was attached to a JNI SBus HBA on an Ultra2 server - until that server decided 
to commit suicide this morning...

Any suggestions?

Dmesg output:

Sep 18 15:05:19 studsvik scsi: [ID 243001 kern.info] /[EMAIL 
PROTECTED],4000/SUNW,[EMAIL PROTECTED] (ifp0):
Sep 18 15:05:19 studsvik        LIP reset occurred; cause f7f7
Sep 18 15:05:19 studsvik scsi: [ID 243001 kern.info] /[EMAIL 
PROTECTED],4000/SUNW,[EMAIL PROTECTED] (ifp0):
Sep 18 15:05:19 studsvik        LIP occurred; cause f7f7
Sep 18 15:05:19 studsvik scsi: [ID 243001 kern.info] /[EMAIL 
PROTECTED],4000/SUNW,[EMAIL PROTECTED] (ifp0):
Sep 18 15:05:19 studsvik        Loop reconfigure in progress
Sep 18 15:05:20 studsvik scsi: [ID 243001 kern.info] /[EMAIL 
PROTECTED],4000/SUNW,[EMAIL PROTECTED] (ifp0):
Sep 18 15:05:20 studsvik        Unable to allocate target structure for switch 
setting 7c
Sep 18 15:05:20 studsvik        reason: Target did not get its hard address
Sep 18 15:05:20 studsvik scsi: [ID 243001 kern.info] /[EMAIL 
PROTECTED],4000/SUNW,[EMAIL PROTECTED] (ifp0):
Sep 18 15:05:20 studsvik        Loop reconfigure done


HSG output:

HLYSHSG1> show this
Controller:
        HSG80 ZG94319138 Software V86G-1, Hardware  E10
        NODE_ID          = 5000-1FE1-0002-60A0
        ALLOCATION_CLASS = 0
        SCSI_VERSION     = SCSI-2
        Not configured for dual-redundancy
        Device Port SCSI address 7
        Time: 18-SEP-2006 14:33:28
        Command Console LUN is disabled
ost PORT_1:
        Reported PORT_ID = 5000-1FE1-0002-60A1
        PORT_1_TOPOLOGY  = LOOP_SOFT (loop up)
        PORT_1_AL_PA     = 02 (negotiated)

LYSHSG1> show d1
    LUN                                      Uses             Used by
------------------------------------------------------------------------------

  D1                                         LYSRAID1     
        LUN ID:      6000-1FE1-0002-60A0-0009-9431-9138-004B
        IDENTIFIER = 2
        Switches:
          RUN                    NOWRITE_PROTECT        READ_CACHE            
          READAHEAD_CACHE        WRITEBACK_CACHE       
          MAX_READ_CACHED_TRANSFER_SIZE = 32
          MAX_WRITE_CACHED_TRANSFER_SIZE = 32
        Access:
                ALL
        State:
          ONLINE to this controller
          Not reserved
        Size:             284381640 blocks
        Geometry (C/H/S): ( 55981 / 20 / 254 )
 
 