On 10/17/06, Reed <[EMAIL PROTECTED]> wrote:
Hi Leon,
If you are running leadville, the simplest way is to "luxadm
fcode_download -p <dir containing you boot code>".
You needn't shift to DOS.
You mean
fcode_download -d <dir containing you boot code>"
Yes, it will upgrade the FCODE.
But it cannot upgrade the HBA firmware.
Thanks,
-- leon
Thanks,
Reed
Leon Koll wrote:
> Hello,
> I am interested to hear what is the best practice procedure of updating the
Emulex HBA's FW and OB code? AFAIK there is no way to do this on SPARC system.
> Do I need to stop the machine and move the HBA to the DOS box and run
LP6DUTIL every time I need to upgrade the FW and OB?
>
> TIA,
> -- leon
>
>
> This message posted from opensolaris.org
> _______________________________________________
> storage-discuss mailing list
> [email protected]
> http://mail.opensolaris.org/mailman/listinfo/storage-discuss
>
_______________________________________________
storage-discuss mailing list
[email protected]