On Nov 23, 2007 6:09 PM, Rob Logan <[EMAIL PROTECTED]> wrote:

>  >  48-bit LBA, DMA, Native Command Queueing, SMART, SMART self-test
>
> some disk's NCQ code is bad, try:
>
> echo "set sata:sata_func_enable = 0x5" >> /etc/system ; echo to turn
> off NCQ
> reboot
>

This seems to have stopped that problem in b77.  NexentaCP RC1 b70 still
crashed and destroy the root zpool.

PS: With b77 it would lock up and not respond to pings. Needed to be hard
reset.

Thanks
Nicholas