On Nov 23, 2007 6:09 PM, Rob Logan <[EMAIL PROTECTED]> wrote: > > 48-bit LBA, DMA, Native Command Queueing, SMART, SMART self-test > > some disk's NCQ code is bad, try: > > echo "set sata:sata_func_enable = 0x5" >> /etc/system ; echo to turn > off NCQ > reboot >
This seems to have stopped that problem in b77. NexentaCP RC1 b70 still crashed and destroy the root zpool. PS: With b77 it would lock up and not respond to pings. Needed to be hard reset. Thanks Nicholas
_______________________________________________ storage-discuss mailing list [email protected] http://mail.opensolaris.org/mailman/listinfo/storage-discuss