Hi Gino,
yes, sxce90 is back working for me.
---------please replace "." with " "------------->
scsi-vhci-failover-override =
"IFT.....A16F-R2221", "f_sym";
device-type-scsi-options-list =
"IFT.....A16F-R2221", "symmetric-option";
symmetric-option = 0x1000000;
<----------------------------------------------------------
# mpathadm show lu /dev/dsk/c4t600D0230000000000088824BC4228801d0s0
Logical Unit: /dev/rdsk/c4t600D0230000000000088824BC4228801d0s2
mpath-support: libmpscsi_vhci.so
Vendor: IFT
Product: A16F-R2221
Revision: 347C
Name Type: unknown type
Name: 600d0230000000000088824bc4228801
Asymmetric: no
Current Load Balance: round-robin
Logical Unit Group ID: NA
Auto Failback: on
Auto Probing: NA
Paths:
Initiator Port Name: 10000000c949892e
Target Port Name: 210000d023a08882
Override Path: NA
Path State: OK
Disabled: no
Initiator Port Name: 10000000c949892f
Target Port Name: 220000d023e08882
Override Path: NA
Path State: OK
Disabled: no
Target Ports:
Name: 210000d023a08882
Relative ID: 0
Name: 220000d023e08882
Relative ID: 0
Best wishes,
Armin
This message posted from opensolaris.org
_______________________________________________
storage-discuss mailing list
[email protected]
http://mail.opensolaris.org/mailman/listinfo/storage-discuss