Hi Gino,

 yes, sxce90 is back working for me. 

---------please replace "." with " "------------->
scsi-vhci-failover-override =
"IFT.....A16F-R2221", "f_sym";

device-type-scsi-options-list =
"IFT.....A16F-R2221", "symmetric-option";
symmetric-option = 0x1000000;
<----------------------------------------------------------




# mpathadm   show lu  /dev/dsk/c4t600D0230000000000088824BC4228801d0s0 
Logical Unit:  /dev/rdsk/c4t600D0230000000000088824BC4228801d0s2
        mpath-support:  libmpscsi_vhci.so
        Vendor:  IFT     
        Product:  A16F-R2221      
        Revision:  347C
        Name Type:  unknown type
        Name:  600d0230000000000088824bc4228801
        Asymmetric:  no
        Current Load Balance:  round-robin
        Logical Unit Group ID:  NA
        Auto Failback:  on
        Auto Probing:  NA

        Paths:  
                Initiator Port Name:  10000000c949892e
                Target Port Name:  210000d023a08882
                Override Path:  NA
                Path State:  OK
                Disabled:  no

                Initiator Port Name:  10000000c949892f
                Target Port Name:  220000d023e08882
                Override Path:  NA
                Path State:  OK
                Disabled:  no

        Target Ports:
                Name:  210000d023a08882
                Relative ID:  0

                Name:  220000d023e08882
                Relative ID:  0