Dear Paul A I think quite a bit more experimentation is needed before copying the top end of Alexis' burner. The evolution is that it was not a premixed flame and the structure was built with that in mind. The change to a premixed flame was not matched by a change in the structure. The result is that there is a very high excess air rate passing through the underside and emerging by the pot. This has the effect of heating a lot of air an lowering the gas temperature beside the pot.
I feel that a 30% improvement in heat transfer efficiency can be achieved by addressing this issue. I have noticed that stove builders fall roughly into two groups: those who build high neat transfer efficiency stove bodies but with mediocre combustion, and those who make really good combustion but neglect the detail of getting good heat transfer. In some cases there is a sort of blind adherence to the idea that a fuel is 'clean' and there is no need for either. 'Clean burning means efficient,' which is nonsense. We should all be paying a lot of attention to both aspects of stove building: efficient combustion and efficient heat transfer. One does not automatically derive from the other. Regards Crispin -----Original Message----- From: [email protected] [mailto:[email protected]] On Behalf Of Paul S. Anderson Sent: Friday, March 16, 2012 6:07 PM To: Discussion of biomass cooking stoves; Paul Olivier Cc: [email protected]; Belonio - Philippines; Corey Berman; Hugh McLaughlin; Bob Fairchild; Alexis; Chua He Subject: [Stoves] Belonio burner top on TLUD stoves was Re: radiant heat capture, total heat measurement Dear all, Paul Olivier commented: (full message is still below, with link to a photo) > ..... which has always led me to wonder why the Belonio burner hole > pattern was not adopted on natural draft units. > If a burner housing were added, I think the unit I experimented with > would work much better. Paul O. raises an excellent point. I think that the moderate complexity of the Belonio hole pattern and secondary air inlet (contrasted to simple concentrator hole) has kept me and probably most others from experimenting with it. Perhaps we incorrectly associated it too much with the forced air (Fan Assisted = FA) aspects of Belonio's rice husk gasifiers. Very little is known about the tops of TLUDs except that some amount of constriction is needed to force the mixing of air and gases. I hope that the engineers (such as Bob Fairchild and student engineers) and others who are now working on TLUD stove issues will seriously consider the Belonio top and related enhancers of combustion of the gases. Paul (Paul A.; not to be confused with Paul O.) -- Paul S. Anderson, PhD Known to some as: Dr TLUD Doc Professor Phone (USA): 309-452-7072 SKYPE: paultlud Email: [email protected] www.gtz.de/de/dokumente/giz2011-en-micro-gasification.pdf (excellent ref.) My website specific for TLUD information: www.drtlud.com = www.DrTLUD.com Quoting Paul Olivier <[email protected]>: > Kevin, > > You say: > *# OK!! A 50% reduction in boiling time is very significant. > What can you now tell us that will enable us to apply it to other stoves > and combustion conditions?* > > I once did an experiment in which I made the 150 Belonio about half its > original height. > I then filled it with chunks of wood and put a Belonio burner on top. > This was a natural draft unit without a fan. > This is what it looked like: > http://dl.dropbox.com/u/22013094/150%20Burner/Image2097.jpg > But looking back on this, I see that there were so many problems with this > burner, > even aside from the fact that it had no burner housing. > > You raise an interesting question, though, which has always led me to wonder > why the Belonio burner hole pattern was not adopted on natural draft units. > If a burner housing were added, I think the unit I experimented with would > work much better. > The central problem that I see with a natural draft unit is an uneven > upward flow of primary air. > At times too much CO2 is created, and some burner holes lose their flames. > Also I would imagine that the inlet of primary air has to be strictly > control to get a consistent outlet of gas at the burner. > > A natural draft TLUD is very complicated, > and I truly marvel at those who get them to work on such a broad variety > of fuels. > > Thanks. > Paul > > Thanks. > Paul ---------------------------------------------------------------- This message was sent using Illinois State University RedbirdMail _______________________________________________ Stoves mailing list to Send a Message to the list, use the email address [email protected] to UNSUBSCRIBE or Change your List Settings use the web page http://lists.bioenergylists.org/mailman/listinfo/stoves_lists.bioenergylists .org for more Biomass Cooking Stoves, News and Information see our web site: http://www.bioenergylists.org/ _______________________________________________ Stoves mailing list to Send a Message to the list, use the email address [email protected] to UNSUBSCRIBE or Change your List Settings use the web page http://lists.bioenergylists.org/mailman/listinfo/stoves_lists.bioenergylists.org for more Biomass Cooking Stoves, News and Information see our web site: http://www.bioenergylists.org/