On 09-05-14 23:24, Venkatesh Shukla wrote:
I have recently got my hands on a Heinrichs Weikamp OSTC3. It has three dives shown inside. But, when I try to download the dives to Subsurface Application, I get the error "Error parsing the samples". Only dive 1 is successfully imported and shown on the application.
It seems that your second dive has all gas mixes disabled, and thus no gas mix is marked as the first gas. The parser assumes there is always one gas marked as the initial gas.
Is this maybe a rebreather dive? The data doesn't seem to indicate this.
Also, when trying to save the dumpfile of the divecomputer, I am getting "Dive data import error".
This is expected, because the ostc3 doesn't support memory dumps. If you run the universal app from the libdivecomputer website, it will write the raw dives to a series of dive_xx.bin files instead.
http://www.libdivecomputer.org/builds/ Jef _______________________________________________ subsurface mailing list [email protected] http://lists.hohndel.org/cgi-bin/mailman/listinfo/subsurface