On 26.09.2014, at 15:02, Davide DB <[email protected]> wrote: Hi,
> Hi Robert could you explain better SCR mode?
I am a bit in a rush, so only briefly:
I discussed this a bit some time ago with John Kendall (one of the GUE
instructors and SCR divers).
It should be safe to only use the steady state solution of the time dependent
O2 content (as it is reached very quickly).
I have a piece of paper with some calculations and a boxed equation that says
ppO2_ss = ppO2_in - (1 -fO2_in) * O2consumption / (SAC * r)
where O2consumption is what the body metabolizes per minute (in l/min) and SAC
is the surface air consumption (in l/min) and r is the ration of droped gas in
the rebreather. Those three parameters should be gotten from the preferences/UI
somewhere.
Does that help?
Best
Robert
--
.oOo.oOo.oOo.oOo.oOo.oOo.oOo.oOo.oOo.oOo.oOo.oOo.oOo.oOo.oOo.oOo.oOo.oOo.oOo.oO
Robert C. Helling Elite Master Course Theoretical and Mathematical Physics
Scientific Coordinator
Ludwig Maximilians Universitaet Muenchen, Dept. Physik
Phone: +49 89 2180-4523 Theresienstr. 39, rm. B339
http://www.atdotde.de
Enhance your privacy, use cryptography! My PGP keys have fingerprints
A9D1 A01D 13A5 31FA 6515 BB44 0820 367C 36BC 0C1D and
DCED 37B6 251C 7861 270D 5613 95C7 9D32 9A8D 9B8F
signature.asc
Description: Message signed with OpenPGP using GPGMail
_______________________________________________ subsurface mailing list [email protected] http://lists.hohndel.org/cgi-bin/mailman/listinfo/subsurface