We cannot zero setpoint value upon import if the current and previous values are zero. This is because on setpoint context a value of 0 means open circuit.
Signed-off-by: Miika Turkia <[email protected]> --- dive.c | 11 +---------- 1 file changed, 1 insertion(+), 10 deletions(-) diff --git a/dive.c b/dive.c index 92637fe..9395c93 100644 --- a/dive.c +++ b/dive.c @@ -1092,7 +1092,7 @@ static void fixup_dive_dc(struct dive *dive, struct divecomputer *dc) int maxdepth = dc->maxdepth.mm; int mintemp = 0; int lastdepth = 0; - int lasto2val[3] = { 0, 0, 0 }, lasto2setpoint = 0; + int lasto2val[3] = { 0, 0, 0 }; int lasttemp = 0, lastpressure = 0, lastdiluentpressure = 0; int pressure_delta[MAX_CYLINDERS] = { INT_MAX, }; @@ -1166,15 +1166,6 @@ static void fixup_dive_dc(struct dive *dive, struct divecomputer *dc) } } - // If there are consecutive identical CCR O2 setpoint readings, throw away the redundant ones. - o2val = sample->setpoint.mbar; - if (o2val) { - if (lasto2setpoint == o2val) - sample->setpoint.mbar = 0; - else - lasto2setpoint = o2val; - } - update_min_max_temperatures(dive, sample->temperature); depthtime += (time - lasttime) * (lastdepth + depth) / 2; -- 1.9.1 _______________________________________________ subsurface mailing list [email protected] http://lists.subsurface-divelog.org/cgi-bin/mailman/listinfo/subsurface