On Sun, Jan 18, 2015 at 07:39:38PM -0200, Tomaz Canabrava wrote: > > Whoa, this deserves a good explanation. Everytime that the mouse > moved in Add mode / Plan mode, or anytime a new dive was displayed > on the Profile, this method would be called and connect the > dataModel to the modelChanged method. This added the slot in a > call-vector that the fired signal would call, adding one call > to the SLOt per ADD / PLAN mouse move ( about 20x/s ) or each > time a new dive was displayed. Quicly filling the vector with > more than 200 - 300 calls to this same SLOT. > > The fix is to only connect one time. this made the ADD / PLAN > mode *so* much smooth... :)
Excellent work, Tomaz. Thanks for catching that. Never occured to me that it would call the same function more than once per "firing" of the signal... /D _______________________________________________ subsurface mailing list [email protected] http://lists.subsurface-divelog.org/cgi-bin/mailman/listinfo/subsurface