27' @ 50m salt water D12 air + AL50 EAN50 ascent 9 / descent 20 GF 45/95 v drop to first depth v last stop at 6m v only switch at required stops bottom SAC 20 deco 18
I have the following deco table: Subsurface (4.9.3.235) dive plan created on 28.10.19 Runtime: 63min depth duration runtime gas ➘ 50m 3min 3min air ➙ 50m 25min 27min ➚ 21m 3min 30min - 21m 1min 31min EAN50 *➚* *18m* *0min* *32min* *-* *18m* *0min* *32min* ➚ 15m 0min 32min - 15m 2min 34min ➚ 12m 0min 34min - 12m 3min 37min ➚ 9m 0min 37min - 9m 4min 41min ➚ 6m 0min 41min - 6m 21min 62min ➚ 0m 1min 63min Again we have 0 minutes problem. As a matter of fact with my Shearwater, same parameters, I get: *Stp Tme Run Gas* 50 bot 27 21/00 21 asc 30 21/00 21 1 31 50/00 18 1 32 50/00 15 2 34 50/00 12 2 36 50/00 9 4 40 50/00 6 23 63 50/00 Any idea or solution?
_______________________________________________ subsurface mailing list [email protected] http://lists.subsurface-divelog.org/cgi-bin/mailman/listinfo/subsurface