On 2/11/19 07:41, tormento wrote:
I am getting errors while importing dives from Perdix AI with its BT dongle (I
don't hava any other to try) while it's own software can import dives correctly.
I select choose Bluetooth mode, find the Perdix and save.
When I try to import, I get:
Connecting to BLE device
Connecting
Then a error windows pops up with "Dive data import error".
image.png
The log tells:
Subsurface: v4.9.3-242-g9c8fbe494db2, built with libdivecomputer
v0.7.0-devel-Subsurface-NG (426a39fc7378cac3f5b1d3983be38d56ab526e78)
INFO: Open: transport=32
INFO: Configure: baudrate=115200, databits=8, parity=0, stopbits=0,
flowcontrol=0
INFO: Timeout: value=3000
INFO: Sleep: value=300
INFO: Purge: direction=3
INFO: Write: size=11, data=0100FF0105002E902000C0
No .bin is generated.
Uncheck the "Save libdivecomputer dumpfile" checkbox. The Shearwater Perdix AI
communication protocol doesn't support memory dumps. Trying to download a memory
dump will always fail with DC_STATUS_UNSUPPORTED.
For the diagnostics purposes, the log file is sufficient for these models.
Jef
_______________________________________________
subsurface mailing list
[email protected]
http://lists.subsurface-divelog.org/cgi-bin/mailman/listinfo/subsurface