Flowrouter only sums up the lanes and doesn't concern itseelf with flow per
lane
So there are two seeprate issues to this:

1) total flow: Looking at time 90, the simulation has a deficit of ~1300
vehs/hour. This could be due to the low aggregegation interval of 1 minute
because flowrouter does not take driving time between detectors into
account. Whenever the flow changes a lot, flowrouter tends to underestimate
total flow. To compensate, set a higher value for option -i

2) vehicle distribution across the lane. This distribution comes out of the
simulation dynamics and depends mostly on
- configuration for insertion lanes and insertion speed
- the parameterization of the vehicle fleet in regard to lane changing
- the distribution of desired speeds

regards,
Jakob



Am Di., 2. Apr. 2019 um 12:43 Uhr schrieb Fredrik Nilsson <
[email protected]>:

> I accidentally attached the Speed over time plot instead of the Flow over
> time plot, it's attached here.
> ------------------------------
> *From:* [email protected] <[email protected]> on
> behalf of Fredrik Nilsson <[email protected]>
> *Sent:* Tuesday, April 2, 2019 12:39
> *To:* Sumo project User discussions
> *Subject:* [sumo-user] Low flow in lane with flowrouter
>
> Hi,
>
> I've been tuning a simulation to match real detector data and I have a
> somewhat odd issue that I was wondering if anyone can perhaps come up with
> a reason for. I have imported the network from OSM and made some slight
> changes, I have attached a picture of the network (blue lines are where
> detectors are present, one per lane) and the detectors whose results I want
> to match to reality are the ones inside the red circle (from the left to
> the right they are detectors 35138, 35139, 35140 and 35141).
>
> I have also attached pictures of the flow over time for both real data and
> simulated data (red is simulation, blue is real data) and a density-flow
> fundamental diagram scatter plot (red is simulaton, blue is real data).
>
> Now, as can be seen on 35138 (the left most lane in the red circle) the
> flow is very low compared to reality and this problem only seems to exist
> on that lane. I have generated the flow and route files with  flowrouter.py
> with 1 minute intervals (the same as the real world data that it was
> generated from).
>
> Can anyone think of a reason why my flow would be so low on this specific
> lane and if perhaps I could make some changes to flowrouter settings to
> make it better?
>
> Sorry for the long question and best regards,
>
> Fredrik
> _______________________________________________
> sumo-user mailing list
> [email protected]
> To change your delivery options, retrieve your password, or unsubscribe
> from this list, visit
> https://www.eclipse.org/mailman/listinfo/sumo-user
>
_______________________________________________
sumo-user mailing list
[email protected]
To change your delivery options, retrieve your password, or unsubscribe from 
this list, visit
https://www.eclipse.org/mailman/listinfo/sumo-user

Reply via email to