Hey guys,

I'm currently running a simulation for one hour with calibrators, but they 
don't behave as they should. The file with the calibrator definitions looks 
like this:

<?xml version="1.0" ?>
<additional xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"; 
xsi:noNamespaceSchemaLocation="http://sumo.dlr.de/xsd/additional_file.xsd";>
<routeProbe begin="0.00" edge="-26953591#1" file="probe.xml" freq="1" 
id="routeProbe_-26953591#1" name="-26953591#1"/>
...
<inductionLoop file="inductionLoop.xml" freq="10" 
id="inductionLoop_-26953591#1_0" lane="-26953591#1_0" pos="-1"/>
...
<calibrator edge="-26953591#1" id="cali_-26953591#1" pos="1" 
routeProbe="routeProbe_-26953591#1">
        <route edges="-26953591#1" id="cali_-26953591#1"/>
        <flow begin="53" departPos="free" departSpeed="max" end="112" 
route="cali_-26953591#1" type="private" vehsPerHour="55.576395141497045"/>
<flow begin="113" departPos="free" departSpeed="max" end="172" 
route="cali_-26953591#1" type="private" vehsPerHour="55.08124042362967"/>
        ...
</calibrator>
</additional>

All calibration intervals are set to 60 seconds, but what I get as a result 
from the variable interval_sampledSeconds in the induction loop file looks like 
this:

[cid:[email protected]]
The result looks like the calibration interval is for the complete hour and not 
for the defined intervals, which leads to a massive insertion of traffic and 
thereby to massive traffic jams.

Do you have any suggestions for me what I need to change in order to make it 
work in the intended way? Thanks in advance!

Best regards
Simon
_______________________________________________
sumo-user mailing list
[email protected]
To unsubscribe from this list, visit 
https://www.eclipse.org/mailman/listinfo/sumo-user

Reply via email to