Hello, this is a known bug which has been fixed in the latest development version ( https://github.com/eclipse/sumo/issues/8692) You can obtain a fixed version at https://sumo.dlr.de/docs/Downloads.php#sumo_-_latest_development_version
Alternatively, - edit your xml file by in a text editor (you can define pos="-100" to count backwards from the end of the lane) - or edit your network so that the geometrical length matches the assigned edge length regards, Jakob Am Fr., 18. Juni 2021 um 21:43 Uhr schrieb Soumya Sharma <[email protected] >: > Hello All, > I am trying to set up instantaneous loop detectors on my SUMO network on > one specific edge. I want the detectors to be located at 100 ft after the > edge begins and 100 ft before the end of the edge. > > I was able to set up the instantaneous loop detectors on all three lanes > at 100 ft from the edge starting point but NETEDIT doesn't allow me to add > instantaneous loop detectors 100 ft before the end of the edge. Could > someone please let me know what the issue might be? > > I have attached the NETEDIT file here for reference. Thanks in advance for > your help! > > -- > Thank you, > Soumya Sharma > Graduate Research Assistant | ITRE > Department of Civil, Construction, and Environmental Engineering > North Carolina State University > *AREMA **Liaison | NC State ITE/AREMA/ASHE Student Chapter * > LinkedIn <https://www.linkedin.com/in/soumya-sharma-7580333b> > > [image: itre.PNG] > > > _______________________________________________ > sumo-user mailing list > [email protected] > To unsubscribe from this list, visit > https://www.eclipse.org/mailman/listinfo/sumo-user >
_______________________________________________ sumo-user mailing list [email protected] To unsubscribe from this list, visit https://www.eclipse.org/mailman/listinfo/sumo-user