Hello,
this is a known bug which has been fixed in the latest development version (
https://github.com/eclipse/sumo/issues/8692)
You can obtain a fixed version at
https://sumo.dlr.de/docs/Downloads.php#sumo_-_latest_development_version

Alternatively,
- edit your xml file by in a text editor (you can define pos="-100" to
count backwards from the end of the lane)
- or edit your network so that the geometrical length matches the assigned
edge length

regards,
Jakob

Am Fr., 18. Juni 2021 um 21:43 Uhr schrieb Soumya Sharma <[email protected]
>:

> Hello All,
> I am trying to set up instantaneous loop detectors on my SUMO network on
> one specific edge. I want the detectors to be located at 100 ft after the
> edge begins and 100 ft before the end of the edge.
>
> I was able to set up the  instantaneous loop detectors on all three lanes
> at 100 ft from the edge starting point but NETEDIT doesn't allow me to add
> instantaneous loop detectors 100 ft before the end of the edge. Could
> someone please let me know what the issue might be?
>
> I have attached the NETEDIT file here for reference. Thanks in advance for
> your help!
>
> --
> Thank you,
> Soumya Sharma
> Graduate Research Assistant | ITRE
> Department of Civil, Construction, and Environmental Engineering
> North Carolina State University
> *AREMA **Liaison | NC State ITE/AREMA/ASHE Student Chapter *
> LinkedIn <https://www.linkedin.com/in/soumya-sharma-7580333b>
>
> [image: itre.PNG]
>
>
> _______________________________________________
> sumo-user mailing list
> [email protected]
> To unsubscribe from this list, visit
> https://www.eclipse.org/mailman/listinfo/sumo-user
>
_______________________________________________
sumo-user mailing list
[email protected]
To unsubscribe from this list, visit 
https://www.eclipse.org/mailman/listinfo/sumo-user

Reply via email to