Hi everyone,

I am evaluating a scenario where I defined E1 detectors (0.1m from the stop 
line) to extract saturation flows at intersections. I am using a W99 model, 
which seems to behave more accurately when I set the time step length to 0.1 
sec.

I compared the E1 detector measurements and classic edge data for a step length 
of 1 s and 0.1 s. The detector results (aggregated to 90 s as this is the cycle 
time of traffic signals in my scenario) appear to be largely different. In 
fact, the total number of detected vehicles is more than 40% different. The 
total number of (entered and left) vehicles according to edge data differs only 
around 0.5%.

Any thoughts or comments on this?

Thanks a lot!

Best
Gabriel